Service Manual
Step
d
Adjust the position of conncetion pipe on
evaporator up wards to remove it.
10.Remove motor and cross flow blade
a
Remove the screws fixing motor clamp and
then remove the motor clamp.
① Remove the screws at the connection
b
place of cross flow blade and motor; lift
the motor and cross flow blade upwards to
remove them.
② Remove the bearing holder sub-assy.
③ Remove the screw fixing step motor and
then remove the step motor.