Outdoor Unit - Panasonic CS-XE15SKUA Service Manual

Hide thumbs Also See for CS-XE15SKUA:
Table of Contents

Advertisement

8.2

Outdoor Unit

SINGLE PHASE
TO INDOOR UNIT
POWER SUPPLY
(BLK)
1
L1
L2
(BLK)
BLK
GRN
BASE PAN
HEATER
3
3
CABINET
1
1
SIDE
PLATE
BLU
YELLOW(YEL)
RED
BLUE
(RED)
(BLU)
(TRADEMARK)
COMP. TERMINAL
THE PARENTHESIZED LETTERS IS
INDICATED ON TERMINAL COVER
Resistance of Compressor Windings
MODEL
CONNECTION
U-V
U-W
V-W
Note: Resistance at 68°F (20°C) of ambient temperature.
(WHT) (RED)
2
3
TERMINAL
(WHT)
(RED)
BOARD
COM3
(RED)
WHT
FUSE3
RED
(20A. 250V)
AC-BLK
WHT
(BLK)
AC-WHT
(WHT)
FG01
(GRN)
HT1
BLU
(BLU)
1
ELECTRONIC
CN-HT1
CONTROLLER
5
(HEATER)
1
HT1 (BLU)
RY-HT1
CN-HT2
ACL (BRW)
5
BRW
ACL (BRW)
ELECTRO MAGNETIC COIL
(4-WAY VALVE)
CU-XE15SK
5RD132XBA21 (Ω)
1.897
1.907
1.882
REACTOR
GRY
L2-
(GRY)
COMMUNICATION
CIRCUIT
FUSE2
(T3.15A L250V)
NOISE FILTER
CIRCUIT
PFC
RECTIFICATION
CIRCUIT
CN-EV
CN-HOT
(WHT)
(BLU)
3
1
6
1
BLU
M
ELECTRO-MAGNETIC COIL
(EXPANSION VALVE)
15
GRY
L2-O
(GRY)
ELECTRONIC
CONTROLLER
SWITCHING
POWER
RECTIFICATION
SUPPLY
CIRCUIT
CIRCUIT
Q10
U
P
V
W
CIRCUIT
N
FUSE1
CN-DCFM
(T2.5A L250V)
(WHT)
CN-TANK
CN-TH1
(WHT)
(WHT)
3
1
4
1
OUTDOOR AIR
TEMP. SENSOR
(THERMISTOR)
COMP TEMP.
PIPING
SENSOR
TEMP. SENSOR
(THERMISTOR)
(THERMISTOR)
REMARKS
BLU : BLUE
BLK : BLACK
WHT : WHITE
RED : RED
YEL : YELLOW
GRY : GRAY
GRN : GREEN
ORG : ORANGE
YEL/GRN : YELLOW/GREEN
BRW : BROWN
3
3
(RED)
RED
U
RED
(BLU)
V
BLU
BLU
MS
(YEL)
3~
YEL
YEL
W
1
1
COMPRESSOR
1
RED
BLK
M
WHT
BLU
FAN
YEL
MOTOR
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-xe15skua

Table of Contents