(CON T'D) EXTER NAL RELA Y C ON TROL (ADDRE SS 1609 -1648)
ADDRESS 1609-1613 (RELAY EVENT 25)
1609
1610
1611
1612
RELAY # AREA Timeout Event ID COND.
L
R
L
R
L
R
L
R
(•)
(•)
ADDRESS 1624-1628 (RELAY EVENT 28)
1624
1625
1626
1627
RELAY # AREA Timeout Event ID COND.
L
R
L
R
L
R
L
R
(•)
(•)
ADDRESS 1639-1643 (RELAY EVENT 31)
1639
1640
1641
1642
RELAY # AREA Timeout Event ID COND.
L
R
L
R
L
R
L
R
(•)
(•)
To program, follow the 5 steps below:
To program, follow the 5 steps below:
STEP 1: RELAY # OPTIONS:
from Relay Module RM3008. Multiple events may be "mapped" to each relay,
up to a maximum of 16 events.
Select the relay number from Table 1 (shown on next page); enter in
corresponding right digit address location (left digit is not used).
STEP 2: AREA OPTIONS:
Each relay event can be assigned to Area 1, Area 2 or both Area 1 &
Area 2.
Select the area from Table 2 (shown on next page); enter in corresponding right digit address
location (left digit is not used).
STEP 3: TIMEOUTS:
Each relay event can be assigned a timeout depending on Alarm Type option.
If Alarm Type (see next page) is selected for timeout in minutes or seconds, select the timeout from Table
3 (shown on next page) in minutes or seconds and enter in corresponding address location (left digit and
right digits). To choose seconds or minutes, see step 5A below. 254 is maximum entry.
STEP 4: EVENT ID CODES:
Select 2-digit Event ID from Table 4 (see next page); enter in corresponding address locations (left and right digit).
STEP 5: RELAY EVENT CONDITION OPTIONS:
condition; also, select a timeout type for each.
5A. Select Alarm Type and Timeout Type from Table 5A (shown on next page); enter in corresponding address location (left
digit).
5B. Select Activation from from Table 5B (shown on next page); enter in corresponding address location (right digit).
X
GEM-P1664 Programming Instructions
ADDRESS 1614-1618 (RELAY EVENT 26)
1613
1614
1615
RELAY # AREA Timeout Event ID COND.
L
R
L
R
L
(•)
(•)
ADDRESS 1629-1633 (RELAY EVENT 29)
1628
1629
1630
RELAY # AREA Timeout Event ID COND.
L
R
L
R
L
(•)
(•)
ADDRESS 1644-1648 (RELAY EVENT 32)
1643
1644
1645
RELAY # AREA Timeout Event ID COND.
L
R
L
R
L
(•)
(•)
The GEM-P1664 supports 8 external relays
Each relay event can be assigned any of the available event IDs from the table.
Each relay event can be assigned an alarm type; and an activation
1616
1617
1618
R
L
R
L
R
L
R
1631
1632
1633
R
L
R
L
R
L
R
1646
1647
1648
R
L
R
L
R
L
R
RELAY # AREA Timeout Event ID
L
(•)
WI1423A 1/06
ADDRESS 1619-1623 (RELAY EVENT 27)
1619
1620
1621
RELAY # AREA Timeout Event ID COND.
L
R
L
R
L
R
L
(•)
(•)
ADDRESS 1634-1638 (RELAY EVENT 30)
1634
1635
1636
RELAY # AREA Timeout Event ID COND.
L
R
L
R
L
R
L
(•)
(•)
[Default = blank (•) blank (•) from
address 1609-1648]
RELAY EVENT OPTIONS
COND.
R
L
R
L
R
L
R
L
(•)
Step
Step
Step
Step
Step
1
2
3
4
Continued
L
NAPCO Security Systems
1622
1623
R
L
R
1637
1638
R
L
R
R
5

Advertisement

Table of Contents
loading

Table of Contents