Advanced Menu (Device Configuration Menu)
The Advanced Menu includes the parameters described in Table 7.
Table 7 The default settings of Advanced Menu
Parametr
English
The Menu Exit – enables exit from menu.
Note: This parameter cannot be edited.
To exit from menu:
In Advanced Menu select P000.
Confirm the selection, push the right button.
Wire Feed Speed (WFS) units – enables change WFS units:
CE (factory default) = m/min;
US = in/min.
Crater Delay - this option is used to skip the Crater sequence
when making short tack welds. If the trigger is released before
the timer expires, Crater will be bypassed and the weld will
end. If the trigger is released after the timer expires, the Crater
sequence will function normally (if enabled).
OFF (0) to 10.0 seconds (default = OFF)
Display Trim as Volts Option – determines how Trim is
displayed:
"Yes" = all trim values are displayed as a voltage;
"No" = the trim is displayed in the format defined in the
weld set.
Note: This option may not be available on all machines. The
power source must support this functionality, or this option will
not appear in the menu.
Arc Start/Loss Error Time - This option can be used to
optionally shut off output if an arc is not established, or is lost
for a specified of time. Error 269 will be displayed if the
machine times out. If the value is set to OFF, machine output
will not be turned off if an arc is not established or arc is lost.
The trigger can be used to hot feed the wire (default). If a
value is set, the machine output will shut off if an arc is not
established within the specified amount of time after the
trigger is pulled or if the trigger remains pulled after an arc is
lost. To prevent nuisance errors, set Arc Start/Loss Error Time
to an appropriate value after considering all welding
parameters (run-in wire feed speed, weld wire feed speed,
electrical stick out, etc).
OFF (0) to 10.0 seconds (default = Off)
Note: This parameter is disabled while welding in Stick, TIG or
Gouge.
Display Workpoint as Amps Option – determines how
workpoint is displayed:
"No" (factory default) = the workpoint is displayed in the
format defined in the weld set.
"Yes" = all workpoint values are displayed as an
amperage.
Note: This option may not be available on all machines. The
power source must support this functionality, or this option will
not appear in the menu.
Feedback Persist – determines how feedback values are
displayed following a weld:
"No" (factory default) – last recorded feedback values will
blink for 5 seconds following a weld, then return to present
display mode.
"Yes" – last recorded feedback values will blink indefinitely
following a weld until a Control or Button is touched, or an
arc is struck.