Lincoln Electric LF 52D Operator's Manual page 12

Hide thumbs Also See for LF 52D:
Table of Contents

Advertisement

User Memory
In user memory only four welding programs can
be stored.
To assign the weld program to user memory:
Use the left button [27] to select the user memory
number (1, 2, 3 or 4) - LED Indicator [28] will light up
selected memory.
Press and hold the left button [27] it until LED
Indicator [28] will blink.
Use the rght control [23] to select the welding
program.
To save the selected program, press and hold the
left button [27] until LED Indicator will stop blinking.
Warning: The list of available programs depends on
the power source.
Quick Access Menu
The user has access to the arc parameters as well as
start and end process parameters according to Table 3
and 4.
Figure 6
To enter the menu:
Press the right Button [25] until the LED Indicator
[24] illuminates the required parameter.
Set the parameter value by the right control [23]. The
set value is automatically saved.
The parameter value is shown on the right display
[20].
Press the right button [25] to go to the next
parameter.
Press the left button [27] to exit.
WARNING
Access to the menu is not available under welding, or if
there is a fault (status LED [18] is not solid green).
Availability of the parameters in the Quick Access Menu
depend on the selected welding program / welding
process.
English
10
English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K14335-1

Table of Contents