9F, No.78, Sec.1, Kwang-Fu Rd.,
San-Chung District,
24158 New Taipei City,
Taiwan
MDSS GmbH
EC REP
Schiffgraben 41
30175 Hannover, Germany
Contract Manufacturer : AViTA (WuJiang) Co.Ltd
Tel: +86-512-8207-8288
Address: No. 858, Jiao Tong Rd., Wujiang Economic Development Zone,
Suzhou City, Jiangsu Province, P.R.C.
Model: NT16, REF :429
China Medical Production License No.: 苏食药监械生产许20040018号
China Product Registration Number: 苏械注准20182200808
Standard: GB/T 21417.1-2008
IB p/n 93-429-00 rev7 (7/2/20)
®
Distributed by:
American Diagnostic Corporation
55 Commerce Drive,
Hauppauge, New York 11788
Inspected in the U.S.A.
Made in China
tel: 631-273-9600, 1-800-232-2670
fax: 631-273-9659
www.adctoday.com
email: info@adctoday.com
0598
Printed in China
Adtemp
TM
Non-Contact
Thermometer
Model 429
User's Manual
PLEASE NOTE:
THIS MEDICAL INSTRUMENT MUST BE
USED ACCORDING TO INSTRUCTIONS TO
ENSURE ACCURATE READINGS.
Questions?
Call ADC toll free at 1-800-232-2670

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADTEMP 429 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Avita ADTEMP 429

  • Page 1 30175 Hannover, Germany THIS MEDICAL INSTRUMENT MUST BE email: info@adctoday.com USED ACCORDING TO INSTRUCTIONS TO Contract Manufacturer : AViTA (WuJiang) Co.Ltd ENSURE ACCURATE READINGS. Tel: +86-512-8207-8288 Address: No. 858, Jiao Tong Rd., Wujiang Economic Development Zone, Questions? Suzhou City, Jiangsu Province, P.R.C.
  • Page 2 A Special 15. Contact Information To register your product visit us at Thank You... www.adctoday.com/register This manual is available online in a variety of languages, Thank you for choosing an ADC ® Adtemp Non-Contact thermometer. follow the links for language options. We're proud of the care and quality that goes into the manufacture of each www.adctoday.com/care and every item that bears our name.
  • Page 3: Table Of Contents

    Recommended separation distances between portable and mobile RF Adtemp 429 - Instruction Manual communications equipment and the 429 IR Thermometer The 429 IR Thermometer is intended for use in an electromagnetic environment in Table of Contents which radiated RF disturbances are controlled. The customer or the user of the 429...
  • Page 4: Symbols

    1. Symbols Guidance and Manufacturer's Declaration Electromagnetic emissions Documentation Symbols The 429 IR Thermometer is intended for use in the electromagnetic environment specified below. The WARNING: The warning statements in this manual identify conditions or practices that customer or the user of the 429 IR thermometer must make sure it is used in such an environment. could lead to illness, injury, or death.
  • Page 5: Introduction / Intended Use

    Miscellaneous Symbols 12. Standards Type BF applied part ASTM E1965-98 EN 12470-5 Battery Level Indications MDD (93/42/EEC) Annex II Low battery - thermometer can still be used 13. Guidance and Manufacturer's Declaration Low battery - the batteries must be replaced before further operation The 429 IR Thermometer is intended for use in the electromagnetic environment specified below.
  • Page 6 Warning: If the accuracy of any measurement is in question or the use of 11. Technical Specifications this thermometer is not appropriate due to patient condition, check the pa- Type Non-Contact infrared thermometer tient's temperature with an alternate method and then check to verify the Model no.
  • Page 7 Caution: Avoid dropping the device or exposing it to heavy shock or vibration. Note that ADC is not responsible for validating the cleaning or disinfection protocols used on this device outside of ADC’s manufacturing site. You Caution: Do not autoclave. Follow only the cleaning procedures described in should determine the requirements for personnel, equipment, and materials this manual.
  • Page 8: Using The Thermometer

    4. Using the Thermometer If the batteries are completely depleted, “Lo” will be displayed along with the low battery symbol. 4a. Controls and Features 1. Use a Phillips head screwdriver to loosen battery cover screw. Remove cover. 2. Remove the batteries. 3.
  • Page 9: 4D.changing The Temperature Scale

    In the event of a repeated The temperature measured is lower than: error message, contact The Adtemp 429 Non Contact Thermometer can display readings 1. Human Mode : your retailer or ADC’s Cus- in either Fahrenheit (F) or Celsius (C). The default temperature 50°F (10°C)
  • Page 10 Note: If the patient’s skin is covered with hair, sweat, or dirt, clean the area 6.Memory Fucntion and wait 10 minutes before taking a measurement. The unit retains the last 30 readings. Note: Ensure that the thermometer is held firmly during measurement and To recall previous readings: that the patient does not move until the measurement is complete.