Annual inspection list for determining safe operation of
a direct vent gas fireplace
1) Inspect and operate the pressure relief mechanism to verify relief mechanisms are free
from obstruction to operate.
2) Clean glass window with a suitable fireplace glass cleaner. Abrasive cleaners must not
be used. Be careful not to scratch the glass when cleaning.
3) Inspect the operation of the flame safety system Pilot or Flame rectification device.
4) Inspect and ensure the lighting of the main burner occurs within 4 seconds of the
main gas valve opening. Visual inspection should match that outlined in the appliance
instruction manual. Inspect primary air openings for blockage.
5) Inspect condition of vent and vent terminal for sooting or obstruction and correct if
present.
6) Vacuum and clean any debris in the firebox that is not supposed to be there.
7) Test and measure the flame failure response time of the flame safety system. It must
de-energize the safety shutoff in no more than 30 seconds.
8) Check all accessible gas-carrying tubes, connections, pipes and other components for
leaks.
Troubleshooting SIT Nova 820
the following is a troubleshooting chart of possible problems:
PROBLEM
SOLUTION
noisy Pilot
locate pilot adjustment screw on gas control
Flame
valve. Flame is decreased by turning adjustment
screw clockwise.
Pilot won't
disconnect remote wires and try to light pilot. If
ignite
pilot now works, remote connections are faulty.
Check wiring diagram figure 30.
Main burner
1. Check wiring (see figure 30)
will not light
2. check wall switch for proper connection
36
Troubleshooting SIT Proflame 2
the following is a troubleshooting chart of possible problems:
PROBLEM
SOLUTION
Pilot Igniter
1. check the MAIn on-oFF switch (typically
won't spark
located below the valve cover) and turn on
2. ensure main power is on or new batteries
are installed in the remote control and backup
battery pack (if available).
3. check the 3.15A fuse in the control box and
replace if necessary
Pilot Igniter
1. Verify the Inlet and Manifold gas Pressure are
sparking, but
within acceptable limits
Pilot burner
2. check all connections to gas valve
will not light
3. check connection to stepper motor (if
available)
Pilot lights , but
1. check and verify all wiring connections as per
Main burner
the wiring diagram.
will not light
2 . Verify the inlet and Manifold Pressure are
within acceptable limits
Pilot lights , but
1. check the Pilot Flame sensor Rod and clean
Main burner
with steel wool or similar.
will not light
2. check the Pilot hood and clean with steel wool
and igniter
if dirty.
continues to
3. Adjust pilot flame using the pilot adjustment
spark
screw if the pilot flame is too long or too short
(Flame should fully engulf the sensor rod and
must be stable).
4. check and make sure the ground wire from
the pilot is connected to the fireplace body.
Fans not
1. Ensure main power is ON (fireplace may be
working
operating on back up batteries).
2. check the 3.15A fuse in the control box and
replace if necessary
If your fireplace still does not operate correctly, consult your local
Montigo dealer.