Section 10: Cleaning and Maintenance

General

• Have the fireplace and installation inspected yearly. The inspection
must include, but is not limited to, the following:
• A visual check of the entire vent system and termination, where
accessible.
• An inspection of the explosion relief flappers and the door
gaskets to ensure a proper seal.
• An inspection of the burner, vent run, and primary air openings.
• An inspection of the gas valve, gas components, and pilot flame.
For your convenience a 1/8" manifold pressure tap is supplied
on the gas valve for a test gauge connection.
• Inspection of all optional equipment; fans, thermostats, remote
control lights, etc.
• For Natural Gas this appliance requires a minimum inlet pressure
of 5.5" W.C. and a manifold pressure of 3.5" W.C.
• For Propane Gas this appliance requires a minimum inlet pressure
of 11" W.C. and a manifold pressure of 10" W.C.
• Always keep the fireplace area clear and free of combustible materials,
as well as gasoline and other flammable vapors and liquids.
• Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control
which has been under water.
• Inspection of glass doors and screen for damage and proper
installation.

Cleaning

When the fireplace is first activated, there may be some smoke and a
visible film may be left on the glass. This is a normal condition, and is
the result of burning of protective coatings on new metal.
• Glass must be cleaned periodically to remove any film (which is
a normal by-product of combustion) which may be visible. Film
can easily be removed by removing the door. Handle the door
carefully, and clean it with non-abrasive, non-ammonia based
glass cleaners. One of the most effective products is Kel-Kem.
• During the initial firing, Silicone seals will "off gas", leaving a
visual deposit of a white substance on combustion chamber
walls. This can easily be removed using normal household
products.
• Use a vacuum cleaner or whisk broom to keep the control
compartment, burner, and firebox free from dust and lint.
NOTICE
Do not use ammonia or abrasive cleaners on the glass, they will
permanently etch the surface. Use an approved gas fireplace cleaner
such as Kel-Kem or White off.
38
Pilot Burner Adjustment. (SIT Nova
820).
The L**DF-ST* is equipped with an adjustable burner, allowing you to
raise or lower the flames. To adjust the flames, locate the black knob
marked 'Hi-Lo', in the centre of the gas control valve (See Figure 26).
To raise the flame height, turn the black knob (located behind the
lower control compartment) counter-clockwise.
To lower the flame height, turn clockwise.
HI-LO
ADJUSTMENT
KNOB
MANIFOLD
PRESSURE TEST
CONNECTION
INLET PRESSURE
GAS CONTROL KNOB (SHOWN IN PILOT POSITION)
Figure 28. 'Hi-Lo' Adjustment on the SIT Nova 820 gas valve

Burner Adjustment: (SIT Proflame 2).

The L**DF-ST* is equipped with an adjustable burner, allowing you to
raise or lower the flames. To adjust the flames, locate the black knob
marked 'Hi-Lo', in the centre of the gas control valve (See Figure 27).
To raise the flame height, turn the black knob (located behind the
lower control compartment) counter-clockwise.
To lower the flame height, turn clockwise.
Manifold Pressure
Manifold Pressure
Test Connection
Test Connection
Inlet Pressure
Inlet Pressure
Test Connection
Test Connection
Figure 28. 'Hi-Lo' Adjustment on the SIT Proflame 2 gas valve.

Pilot Burner Adjustment.

1. Locate Pilot Adjustment Screw. (See figure 26 or 27.)
2. Adjust pilot screw to provide properly sized flame as shown.
3. After installing or servicing, leak test with
a soap solution with main burner on. Coat
pipe and tubing joints, gasket etc. with soap
solution. Bubbles indicate leaks. Tighten any
areas where the bubbles appear until the
bubbling stops completely.
Operation
PILOT
ADJUSTMENT
POWER
SCREW
GENERATOR
WALL
SWITCH
Pilot Adjustment Screw
Pilot Adjustment Screw