Cooling And Heating Data Sheet In Rated Frequency; Noise Curve - Gree GWH18YD-K6DNA1A Service Manual

Hide thumbs Also See for GWH18YD-K6DNA1A:
Table of Contents

Advertisement

Service Manual

2.4 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling
condition(°C)
(DB/WB)
Indoor
Outdoor
27/19
35/24
Heating:
Rated heating
condition(°C)
(DB/WB)
Indoor
Outdoor
20/-
7/6
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5m.

2.5 Noise Curve

Outdoor side noise when blowing
64
62
60
58
5 6
5 4
52
5 0
15
30
Compressor frequency(Hz)
Technical Information
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
18K
0.9 to 1.1
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
18K
2.8 to 3.0
45
60
Cooling
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°C)
T2 (°C)
12 to 14
75 to 37
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°C)
T2 (°C)
70 to 35
2 to 4
Indoor side noise when blowing
6 0
5 0
40
30
2 0
75
Heating
Fan speed of
Fan speed of
indoor unit
outdoor unit
Super High
High
Fan speed of
Fan speed of
indoor unit
outdoor unit
Super High
High
SL
L
ML
M
Indoor fan motor rating speed
Compressor
frequency
(Hz)
52
Compressor
frequency
(Hz)
65
MH
H
SH
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwh18yd-k6dna1a/iGwh18yd-k6dna1a/o

Table of Contents