Removal Procedure; Removal Procedure Of Indoor Unit - Gree GWH18YD-K6DNA1A Service Manual

Hide thumbs Also See for GWH18YD-K6DNA1A:
Table of Contents

Advertisement

Service Manual

11. Removal Procedure

11.1 Removal Procedure of Indoor Unit

Step
1.Remove filter
a.
Open the panel.
b.
Loosen the clasp shown and
then pull the left filter and right filer
outwards to remove them.
2.Remove horizontal louver
Push out the axile bush on horizontal
louver. Bend the horizontal louver with
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
Installation and Maintenance
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.
Procedure
Panel
Left filter and right filer
horizontal
louver
Horizontal louver
Location of step motor
Axile bush
87