Gev Models - Trane Axiom GEH-E006 Installation, Operation And Maintenance Manual

Water source heat pump, horizontal/vertical
Hide thumbs Also See for Axiom GEH-E006:
Table of Contents

Advertisement

GEV Models

Digits 1–3 — Unit Configuration
GEV = Standard Efficiency Vertical
Digit 4 — Development Sequence
G
Digits 5–7 — Nominal Size (MBH)
006 = 6.0 MBH
009 = 9.0 MBH
012 = 12.0 MBH
015 = 15.0 MBH
018 = 18.0 MBH
024 = 24.0 MBH
030 = 30.0 MBH
036 = 36.0 MBH
042 = 42.0 MBH
048 = 48.0 MBH
060 = 60.0 MBH
Digit 8 — Voltage (Volts/Hz/Phase)
4 = 460/60/3
7 = 265/60/1
A = 208-230/60/1
B = 208-230/60/3
Digit 9 — Heat Exchanger
1 = Copper-Water Coil
2 = Cupro-Nickel Water Coil
7 = Insulated Copper-Water Coil/Suction Line
8 = Insulated Cupro-Nickel Water Coil/
Suction Line
Digit 10 — Design Sequence
A First Design Sequence
Digit 11 — Refrigeration Circuit
0 = Heating and Cooling Circuit
2 = Heating and Cooling Circuit with Hot Gas
Reheat
3 = Heating and Cooling Circuit with
Waterside Economizer
4 = Heating and Cooling Circuit with
Waterside Economizer, Hot Gas Reheat
WSHP-SVX01Y-EN
Digit 12 — Blower Configuration
K = Variable ECM Motor, Constant Torque
Digit 13 — Freeze Protection
A = 20°F Freezestat
B = 35°F Freezestat
Digit 14 — Open Digit = 0
Digit 15 — Supply-Air Arrangement
T = Top Supply-Air Arrangement
B = Back Supply-Air Arrangement
Digit 16 — Return-Air Arrangement
L = Left Return-Air Arrangement
R = Right Return-Air Arrangement
Digit 17 — Control Types
B = Tracer® ZN524 Controls
D = Deluxe 24V Controls
H = UC400/B
J = UC400B w/Air-Fi® Wireless
Communications
Digit 18 — Tstat/Sensor Location
0 = Wall Mounted Location
Digit 19 — Fault Sensors
1 = Condensate Overflow Sensor
3 = Condensate Overflow and Filter
Maintenance Timer
6 = Condensate Overflow and Fan Status
J = Fan Status, Filter Maintenance Timer and
Condensate Overflow Sensor
Digit 20 — Temperature Sensor
0 = No Additional Temperature Sensor
1 = Entering Water Sensor
Digit 21 — Insulation
1 = Matte Faced Insulation
2 = Foil Faced Insulation
M M o o d d e e l l N N u u m m b b e e r r D D e e s s c c r r i i p p t t i i o o n n
Digit 22 — Electric Heat Option
0 = No Electric Heat
6 = Factory Mounted External Boilerless Low
Electric Heat
7 = Factory Mounted External Supplemental
Low Electric Heat
8 = Field Mounted External Boilerless Electric
Heat
9 = Field Mounted Supplemental Electric Heat
A = Factory Mounted External Boilerless
Medium Electric Heat
B = Factory Mounted External Supplemental
Medium Electric Heat
C = Factory Mounted External Boilerless High
Electric Heat
D = Factory Mounted External Supplemental
High Electric Heat
Digit 23 — Unit Mounted Disconnect
0 = No Unit Mounted Disconnect
2 = Unit Mounted Disconnect
Digit 24 — Filter Type
1 = 1-inch Throwaway Filter
2 = 2-inch Throwaway Filter
4 = 2-inch MERV 8
5 = 2-inch MERV 13
Digit 25 — Acoustic Arrangement
1 = Standard Sound Attenuation
2 = Deluxe Sound Attenuation
Digits 26–36 — Does Not Apply
00000000000 = Digits 26-36 are not
applicable to the GEH or GEV products
Digit 37 — Ducted Filter Rack
0 = Non-ducted filter rack
A = Ducted Filter Rack (Side Access/LH—RH)
Digit 38 — Isolation Valve
0 = No Isolation Valve
1 = Factory Mounted Isolation Valve
Digit 39 — Power Connection
1 = Single Point
2 = Dual Point (Electric Heat Power Separate
from Unit)
Digit 40 — Drain Pan
A = Polymer Drain Pan
B = Stainless Steel Drain Pan
Model Number Note:
Note: Back Supply, Electric Heat and Deluxe
Sound option are avalible in later
product release.
7