Ferroli BlueHelix HiTech RRT C Instructions For Use, Maintenance And Installation Manual page 332

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 296
Index Description
Fan minimum speed
P62
Fan On speed
P63
Fan maximum speed
P64
Not implemented
P65
Valve frequency
P66
Installation C10/C11
P67
Flue parameter
P68
* Restore Factory Values
To restore all the parameters to the factory values, set parameter b29 to 10 and confirm. After
which, it is necessary to restore parameter b02 to the correct value, according to the type of boiler.
Parameter b27 will be automatically set to 5.
332
BlueHelix HiTech RRT C
Range
DO NOT MODIFY
(The parameters are automatically updated)
DO NOT MODIFY
(The parameters are automatically updated)
DO NOT MODIFY
(The parameters are automatically updated)
--
0 - 1
0 - 1
0 ÷ 10 (modify according to flue table)
cod. 3541V300 - Rev. 00 - 02/2021
Default
G20/G230:
BlueHelix HiTech RRT 24 C = 47
BlueHelix HiTech RRT 28 C = 47
BlueHelix HiTech RRT 34 C = 49
G30/G31:
BlueHelix HiTech RRT 24 C = 49
BlueHelix HiTech RRT 28 C = 49
BlueHelix HiTech RRT 34 C = 48
G20/G230:
BlueHelix HiTech RRT 24 C = 160
BlueHelix HiTech RRT 28 C = 160
BlueHelix HiTech RRT 34 C = 140
G30/G31:
BlueHelix HiTech RRT 24 C = 152
BlueHelix HiTech RRT 28 C = 152
BlueHelix HiTech RRT 34 C = 132
G20/G230:
BlueHelix HiTech RRT 24 C = 140
BlueHelix HiTech RRT 28 C = 172
BlueHelix HiTech RRT 34 C = 194
G30/G31:
BlueHelix HiTech RRT 24 C = 134
BlueHelix HiTech RRT 28 C = 156
BlueHelix HiTech RRT 34 C = 186
1
1
0
1
EN

Advertisement

Table of Contents
loading

Table of Contents