Service Manual
Resistance Table of Discharge Temperature Sensor for Outdoor (50K)
o
Temp(
C) Resistance(kΩ)
-29
853.5
-28
799.8
-27
750
-26
703.8
-25
660.8
-24
620.8
-23
580.6
-22
548.9
-21
516.6
-20
486.5
-19
458.3
-18
432
-17
407.4
-16
384.5
-15
362.9
-14
342.8
-13
323.9
-12
306.2
-11
289.6
-10
274
-9
259.3
-8
245.6
-7
232.6
-6
220.5
-5
209
-4
198.3
-3
199.1
-2
178.5
-1
169.5
0
161
1
153
2
145.4
3
138.3
4
131.5
5
125.1
6
119.1
7
113.4
8
108
9
102.8
84
o
Temp(
C)
Resistance(kΩ)
10
98
11
93.42
12
89.07
13
84.95
14
81.05
15
77.35
16
73.83
17
70.5
18
67.34
19
64.33
20
61.48
21
58.77
22
56.19
23
53.74
24
51.41
25
49.19
26
47.08
27
45.07
28
43.16
29
41.34
30
39.61
31
37.96
32
36.38
33
34.88
34
33.45
35
32.09
36
30.79
37
29.54
38
28.36
39
27.23
40
26.15
41
25.11
42
24.13
43
23.19
44
22.29
45
21.43
46
20.6
47
19.81
48
19.06
o
Temp(
C) Resistance(kΩ)
49
18.34
50
17.65
51
16.99
52
16.36
53
15.75
54
15.17
55
14.62
56
14.09
57
13.58
58
13.09
59
12.62
60
12.17
61
11.74
62
11.32
63
10.93
64
10.54
65
10.18
66
9.83
67
9.49
68
9.17
69
8.85
70
8.56
71
8.27
72
7.99
73
7.73
74
7.47
75
7.22
76
7.00
77
6.76
78
6.54
79
6.33
80
6.13
81
5.93
82
5.75
83
5.57
84
5.39
85
5.22
86
5.06
87
4.90
Service Manual
o
Temp(
C)
Resistance(kΩ)
88
4.75
89
4.61
90
4.47
91
4.33
92
4.20
93
4.08
94
3.96
95
3.84
96
3.73
97
3.62
98
3.51
99
3.41
100
3.32
101
3.22
102
3.13
103
3.04
104
2.96
105
2.87
106
2.79
107
2.72
108
2.64
109
2.57
110
2.50
111
2.43
112
2.37
113
2.30
114
2.24
115
2.18
116
2.12
117
2.07
118
2.02
119
1.96
120
1.91
121
1.86
122
1.82
123
1.77
124
1.73
125
1.68
126
1.64
Installation and Maintenance
145

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nbl4-09οdu32Nbl4-12idu32Nbl4-12οdu32

Table of Contents