Step
7. Remove electric box assy
a
Loosen the connection clasps between
shield cover of electric box sub-assy and
electric box, and then remove the shield
cover of electric box sub-assy.
b
① Take off the water retaining sheet.
Remove the cold plasma generator by
screwing off the locking screw on the
generator.
② Take off the indoor tube temperature
sensor.
③ Screw off 1 grounding screw.
④ Remove the wiring terminals of motor and
stepping motor.
⑤ Remove the electric box assy.
c
Twist off the screws that are locking
each lead wire and rotate the electric
box assy.
Twist off the screws that are locking the
wire clip. Loosen the power cord and
remove its wiring terminal. Lift up the
main board and take it off.
118
68
Procedure
Shield cover of electric
box sub-assy
Grounding screw
Cold plasma
generator
Screw
Water retaining
sheet
Screw
Screw
Clasps
Electric box
Indoor tube
temperature
Electric box assy
sensor
Main board
Power cord
Screw
Wire clip
Installation and Maintenance
Installation and Maintenance
Service Manual
Service Manual
Wiring
terminal
of motor
Wiring
terminal
of stepping
motor