Introduction

This chapter explains how to install the EM3296 V4, including general requirements, housing design, and physical and
optical information.
Caution: Do not touch the imaging lens when installing the engine. Be careful not to leave fingerprints on the lens.
Caution: Do not touch the illumination LED during handling. Improper handling may damage the LED.

General Requirements

ESD

ESD protection has been taken into account when designing the EM3296 V4. However, due to limited board space,
additional ESD protection, such as TVS protection, is not provided on the engine's I/O interface. It is advised to take
corresponding protection measures when integrating the engine.
The engine is shipped in ESD safe packaging. Always exercise care when handling the engine outside its package. Be
sure grounding wrist straps and properly grounded work areas are used.

Dust and Dirt

The EM3296 V4 must be sufficiently enclosed to prevent dust particles from gathering on the lens and circuit board. Dust
and other external contaminants will eventually degrade the engine's performance.

Ambient Environment

The following environmental requirements should be met to ensure good performance of the EM3296 V4.
Table 2-1
Operating Temperature
Storage Temperature
Humidity
5

Chapter 2 Installation

-20° C to 60° C
-40° C to 70° C
5% ~95% (non-condensing)