Page 1
Hohem Gimbal Tool(Please install the driver CP210X before start the tool) ; Before the calibrate process, please make sure the gimbal is power off. Connect the gimbal to your PC by using USB cable. Check the port number of gimbal by Computer Management.
Page 2
Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com Put the gimbal like this picture, and absolutely insuring the gimbal is still Calibration of the six surfaces of the accelerometer. According to at the horizontal. And then click “Init Gyro”. At this moment, data will the steps calibrate the six surfaces step by step.
Page 3
Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The red color turns green color The red color turns green color...
Page 4
Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The red color turns green color The red color turns green color...
Page 5
Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The red color turns green color The red color turns green color After finished the six surfaces calibration, click “Save All”. It will appear “Calibration Acc success”. And the calibration is finished. (Attention! Does the “Save All” step)
Page 6
The latest version of Hohem Gimbal Tool for Mac OS 2.Please make sure the Gimbal is Power off before starting the calibration.. 3.Connect the gimbal’s USB port to the PC by the provided USB cable and last Open“System Preferences”----“Security&Privacy”...
Page 7
Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com 5.It will require to install the serial driver if it is the first to use this tool, 7.Put the gimbal like this picture, and absolutely insuring the gimbal is the tips as below: still at the horizontal. And then click “Init Gyro”. At this moment, data will appear on the three data frames of the gyro.
Page 8
Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com 8. Calibration of the six surfaces of the accelerometer. According to the steps calibrate the six surfaces step by step. Put the gimbal like following every picture. And click “Calibr Acc” until the red color turns green color . That means the accelerometer data is green.
Page 9
Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The data turns green color The data turns green color...
Page 10
Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The data turns green color The data turns green color...
Page 11
Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The data turns green color 9. After finished the six surfaces calibration, click “Save All”. It will appear “Acc Calibration Succeed!”. And the calibration is finished. (Attention! Does the “Save All” step) ----------------End-----------------...