On-line calibration

Advertisement

Quick Links

BUFF On-line Calibration V1.0
For Windows
Please visit the official website Download Center
service-and-support/download-center?lang=en
documentations:
Hohem Gimbal Tool(Please install the driver CP210X before start the tool) ;
1.
Before the calibrate process, please make sure the gimbal is power off.
Connect the gimbal to your PC by using USB cable.
2.
Check the port number of gimbal by Computer Management.
(Right click the "Computer"—Click the "Manage"—Enter the "Computer
Management"—Click the "Device Manager"—"Ports"—"Communication
port"
1
Hohem Techonology Co.,Ltd http://www.hohem-tech.com
www.hohem-tech.com/
to download following
Tel:0755-86573216 Email:service@hohem-tech.com
3.
Enter the Hohem Gimbal Tool;
4.
The software will recognize the port number automatically(if the
port number is wrong ,please click "Search Serial", then choose the
port number manually)
5.
Following shown the position, after choose the right port number
and click "Open Serial" .
6.
Click "Attitude Calibration" to enter the interface of attitude
calibration.

Advertisement

loading

Summary of Contents for Hohem iSteady BUFF

  • Page 1 Hohem Gimbal Tool(Please install the driver CP210X before start the tool) ; Before the calibrate process, please make sure the gimbal is power off. Connect the gimbal to your PC by using USB cable. Check the port number of gimbal by Computer Management.
  • Page 2 Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com Put the gimbal like this picture, and absolutely insuring the gimbal is still Calibration of the six surfaces of the accelerometer. According to at the horizontal. And then click “Init Gyro”. At this moment, data will the steps calibrate the six surfaces step by step.
  • Page 3 Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The red color turns green color The red color turns green color...
  • Page 4 Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The red color turns green color The red color turns green color...
  • Page 5 Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The red color turns green color The red color turns green color After finished the six surfaces calibration, click “Save All”. It will appear “Calibration Acc success”. And the calibration is finished. (Attention! Does the “Save All” step)
  • Page 6 The latest version of Hohem Gimbal Tool for Mac OS 2.Please make sure the Gimbal is Power off before starting the calibration.. 3.Connect the gimbal’s USB port to the PC by the provided USB cable and last Open“System Preferences”----“Security&Privacy”...
  • Page 7 Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com 5.It will require to install the serial driver if it is the first to use this tool, 7.Put the gimbal like this picture, and absolutely insuring the gimbal is the tips as below: still at the horizontal. And then click “Init Gyro”. At this moment, data will appear on the three data frames of the gyro.
  • Page 8 Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com 8. Calibration of the six surfaces of the accelerometer. According to the steps calibrate the six surfaces step by step. Put the gimbal like following every picture. And click “Calibr Acc” until the red color turns green color . That means the accelerometer data is green.
  • Page 9 Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The data turns green color The data turns green color...
  • Page 10 Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The data turns green color The data turns green color...
  • Page 11 Hohem Techonology Co.,Ltd http://www.hohem-tech.com Tel:0755-86573216 Email:service@hohem-tech.com The data turns green color 9. After finished the six surfaces calibration, click “Save All”. It will appear “Acc Calibration Succeed!”. And the calibration is finished. (Attention! Does the “Save All” step) ----------------End-----------------...