Panasonic CS-ZC15MKY-3 Service Manual page 20

Table of Contents

Advertisement

Bend the Embedded Piping
Adjust the piping slightly downwards.
In case of left piping how to insert the connection
cable and drain hose.
For the right piping, follow the same procedure.
10.2.4 Connect the Cable to the Indoor Unit
1
Remove the control board cover by loosening the screw.
2
Connect the power supply cord and connecting cable between
indoor unit and outdoor unit according to the diagram below.
Cable connection to the power supply through Isolating Devices
o
(Disconnecting means).
Connect the approved PVC sheathed or polychloroprene
o
sheathed power supply cord 3 x 1.5 mm
2
2.5 mm
(2.25HP) type designation IS 694 or 60245 IEC 57
or heavier cord to the terminal board, and connect the other
end of the cable to Isolating Devices (Disconnecting means).
Do not use joint power supply cord. Replace the wire if the
o
existing wire (from concealed wiring, or otherwise) is too
short.
In unavoidable case, joining of power supply cord between
o
isolating devices and terminal board of air conditioner shall
be done by using approved socket and plug rated 16A.
Wiring work to both socket and plug must follow to national
wiring standard.
Connection cable 6 between indoor unit and outdoor unit shall be approved type PVC sheathed or
o
polychloroprene sheathed 3 x 1.5mm
Do not use joint connection cable. Replace the wire if the existing wire (from concealed wiring, or otherwise)
is too short.
How to pull the piping and drain hose out, in case of
the embedded piping.
2
(1.75HP) or 3 x
2
flexible cord.