Switching Properties - Siemens SIMATIC NET SCALANCE XP-200 Operating Instructions Manual

Industrial ethernet switches
Table of Contents

Advertisement

Technical specifications

8.6 Switching properties

8.6
Switching properties
The switching properties listed below apply to the SCALANCE XP-200.
Switching properties
Aging time
Maximum frame size
Max. number of learnable ad‐
dresses
Response to LLDP frames
Response to spanning tree
BPDU frames
CoS acc. to IEEE 802.1Q
QoS priority queues
Switching technique
Latency
Full wire speed switching
Note
The number of SCALANCE XP-200 modules connected in a line influences the frame delay. When
a frame passes through the IE switch, this is delayed by the store-and-forward function of the
SCALANCE XP-200 by 10-130 microseconds (at 100 Mbps).
84
Can be configured (default value: 30 seconds)
1632
8192
Blocking
Forwarding
Yes
4
Store and forward
10 microseconds
Frame length (bytes)
64
128
256
512
1024
1280
1518
Number of frames per second (at 100 Mbps)
148810
84459
45290
23496
11973
9615
8127
Operating Instructions, 03/2021, C79000-G8976-C428-08