Siemens SIMATIC NET SCALANCE XP-200 Operating Instructions Manual page 65

Industrial ethernet switches
Table of Contents

Advertisement

Signaling faults
• The signaling of errors by the signaling contact is synchronized with the fault LED "F", see
section ""F" LED (Page 29)".
All errors that the fault LED "F" indicates (freely configurable) are also signaled by the
signaling contact.
• If an internal fault occurs, the fault LED "F" lights up and the signaling contact opens.
• If you connect a communications node to an unmonitored port or disconnect it, this does not
cause an error message.
• The signaling contact remains open until one of the following events occurs:
– The problem is eliminated.
– The current status is entered in the fault mask as the new desired status.
Connecting the signaling contact
1. Connect the plug and socket. Make sure that they lock in place correctly.
2. Tighten the knurled screw (torque 1 Nm).
SCALANCE XP-200
Operating Instructions, 03/2021, C79000-G8976-C428-08
Connecting up
6.5 Signaling contact
65

Advertisement

Table of Contents
loading

Table of Contents