No�fica�ons
Alarm
When the alarm is triggered the system will provide feedback to the user. Upon disarm,
the system will beep 4x and flash the LED to indicate the Alarm Trigger Zone.
1 Shock
2 Trunk / Hood
3 Door
Remote Start
If the remote start fails to start the vehicle, the system will flash the vehicle parking
lights to indicate the cause.
1 Run�me Expired
2 Remote Shutdown
3 Brake On
4 Manual Mode
5 Hood Open
6 Low / No Tach
7 Tach Programming
8 High Tach
Chirp Delete
System ARM/DISARM chirps can be toggled ON or OFF without entering the Feature
Bank programming.
Turn the igni�on key ON/OFF.
1.
Press and release the valet button three (3) �mes.
2.
The system will respond with one (1) chirp for ON and two (2) Chirps for OFF. This
feature will not affect alarm trigger or programming.
User Programmable LED
System LED no�fica�ons can be turned ON or OFF without entering Feature Bank
programming.
Turn the igni�on key ON/OFF, ON/OFF.
1.
Press and hold valet button for five (5) seconds.
2.
The LED will flash one (1) �me for ON, two (2) �mes for OFF. This feature will not affect
LED flash during programming.
Remote Programming
The APSSECRS does not include an RF remote kit. The RF remote kit Includes two (2)
remotes, one (1) antenna, and one (1) cable. When added, remotes must be programmed
to the system. Remote Programming is located in Feature Bank 1. To enter Remote Auto
Programming:
Turn the igni�on key to ON.
1.
Press and release the valet button three (3) �mes. System will beep and flash the
2.
parking lights one (1) �me.
Press the lock button on each remote. The system will beep one (1) �me to indicate the
remote has been programmed. If programming one (1) button remotes, press the Start
button. Only primary remote func�ons are auto programmed. This Includes Lock, Unlock,
and Trunk/Start.
If using AUX output control, you must manually program the AUX output channels to
the remote. Please see the complete installa�on guide for manual remote programming
instruc�on.
Note: If programming 2-Way remotes, wait for the remote to beep before programming
addi�onal remotes. This beep is confirma�on that a 2-Way response has been received
from the main module.
Feature Programming
The APSSECRS Feature Banks can be programmed by using the valet button and remote.
To enter Feature Bank programming:
Turn the igni�on key to ON.
1.
Press and release the valet button three (3) �mes. System will beep and flash lights
2.
one (1) �me for Feature Bank 1, Remote Programming.
Cycle igni�on key OFF/ON. System will beep and flash lights two (2) �mes for
3.
Feature Bank 2.
Press valet button to cycle features. LED will flash to display feature number.
4.
Press lock button to cycle op�ons. System will beep to indicate op�on number.
5.
6.
Cycle igni�on key OFF/ON. System will beep and flash lights three (3) �mes for
Feature Bank 3.
Press valet button to cycle features. LED will flash to display feature number.
7.
8.
Press lock to cycle op�ons. System will beep to indicate op�on Number.
Tach Programming
The installer must manually configure the Engine Confirma�on method in Feature Bank
3, Feature 5. The default method is "Tach". When using the default "Tach" method, the
vehicle tach rate must be programmed. To enter tach rate programming:
Turn the igni�on key ON.
1.
Press and release the valet button three (3) �mes.
2.
Turn the igni�on key OFF.
3.
Press and hold valet button.
4.
While holding valet button, start the engine using the key.
5.
6.
Hold the valet button for approximately ten (10) seconds. If connected to the vehicle
Tach source, the system will flash the parking lights one (1) �me every second.
Release the valet button. The system will turn on the parking lights for two (2)
7.
seconds to indicate the tach rate is programmed.
The tach rate can also be programmed without the use of a valet button. This is helpful
when using the OEM remote of CarLink system to control this module. To program the tach
rate without a valet button:
1. Turn the igni�on key to the ON posi�on and start the vehicle's engine.
2. Wait for Engine RPM to lower to a normal idle.
3. Press and hold the vehicle's brake pedal.
4. Press the LOCK button on the OEM remote or the Carlink App.
Note: Programming tach signal via OEM or Telema�cs control is only available on Firmware
v1.47 or Higher.
Data Protocol Selec�on
The default data port protocol of this model is ADS (iDatalink 2-Way). This model is capable
of detec�ng the correct data port protocol (ADS or DBI) and automa�cally configuring
Feature Bank 2; Feature 18. To ini�alize the detec�on procedure:
Press and hold the valet button.
1.
Cycle the vehicle's Igni�on ON/OFF two (2) �mes.
2.
Release the valet button.
3.
The system will automa�cally detect and set the correct data port protocol, ADS or DBI.
Note: This feature is only available on module firmware v2.0 or higher.
The Feature Banks below can also be programmed using the FlashLogic Weblink or Weblink Mobile.
Feature Bank 2
1 Chirp
2 Chirp
1 Lock / Unlock Func�on
500ms
3.5sec
2 Igni�on Lock
OFF
ON
3 Igni�on Unlock
OFF
Unlock All
4 Exterior Illumina�on
OFF
With Arm
5 Auto Relock
OFF
Auto Lock Only
OFF
6 Auto Arming / Locking
Auto Arm Only
7 No�fica�on Sound
Both
Siren
8 Horn Timing
16ms
30ms
9 Valet Override Method
Valet
Custom Code
10 Driver Priority Unlock
OFF
ON
11 Silent Choice
OFF
From Transmitter
12 Security Profile
All On
Doors off
Negative
13 Door Trigger Input
Posi�ve
14 Park Light / Trunk Swap
OFF
ON
15 Data Port Protocol
ADS
DBI
16 Dome Light Delay Timer
OFF / Program
15sec
17 Alarm Trigger Legnth
30sec
45sec
Feature Bank 3
1 Chirp
2 Chirp
1 Defrost Output
Pulsed
10min
2 RS Start No�fica�on
ON
OFF
3 RS Run�me
15min
20min
4 RS Parking Lights
Steady
Flashing
5 Engine Confirma�on
Tach
Voltage
6 Voltage Level
>0.5v B4 Start
<0.5v B4 Start
7 Igni�on 2 Output
Ignition
Accessory
Ignition
8 Igni�on 3 Output
Accessory
9 Accessory Output
Accessory
Igni�on
10 Transmission
Auto
Manual
11 Max Crank Time
0.8sec
1.0sec
12 Diesel Delay
OFF
Diesel 5
13 Temperature Start
OFF
14F
14 Crank Dura�on
Averaging
Preset
Shunt until Clear
15 RS Shock Override
Shunt RS Cycle
16 Turbo Timer
OFF
3min
17 Start Ac�va�on
Two Press
One Press
18 RS Lock Func�on
No Change
UL Before L A�er
19 Factory Disarm Output
Single Pulse
Double Pulse
20 Addi�onal Unlock Pulse
No Pulse
IGN, ACC, GWR
Dome Delay Programming
This system can be programmed to ignore the vehicle's theater dimming dome light. This
feature will be used when connec�ng the door trigger input to the dome light circuit for
alarm trigger.
Start with all doors closed and the vehicle dome light off.
Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.
1.
Open and close the driver door.
2.
The system will monitor the dome light circuit. When the dome light turns off the system
will set the delay �me and add an addi�onal two (2) seconds.
Dome Delay Reset
1. Key ON/OFF, ON/OFF, ON/OFF.
2. Press and hold valet button for five (5) seconds.
The system will beep one (1) �me to indicate reset is complete.
Programmable Input Control
Programmable Input Control allows any PIC be configured to one of the op�ons listed
below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.
Door Trigger
Full Shock Trigger
Trunk Trigger
Parking Brake
Hood Trigger
Brake
N.C. Door Trigger
External Start Ac�va�on
Pre-Warn Shock Trigger Diesel Glow Plug
Op�ons
3 Chirp
4 Chirp
5 Chirp
500ms L, DBL UL
DBL L, 500ms UL
DBL L, DBL UL
Unlock Driver
With Disarm
With Arm & Disarm
Auto Lock & Arm
Auto Lock & Arm
Horn
40ms
50ms
10ms
Stand Alone Valet
OEM Style
Hood / trunk Off
All Off
All On w/ OEM RS
30sec
45sec
60sec
60sec
90sec
120sec
Op�ons
3 Chirp
4 chirp
5 Chirp
RS Run�me
45min
60min
5min
Data
Hybrid
Start
Start
Start
1.5sec
2.0sec
3.0sec
Diesel 10
Diesel 15
Diesel 20
5F
0F
-4F
Shunt From TX
5min
10min
Three Press
UL Before Start
Lock A�er Start
350ms
500ms
800ms
IGN,ACC,GWR,PASD
Nega�ve Output Control (NOC)
Nega�ve output control allows any NOC to be programmed for any one of the op�ons
below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.
Lock
Ground While Armed
Unlock
Ground While Disarmed
2nd Unlock
Domelight
Trunk
Headlight
Remote Start Status
Defrost
Igni�on
LED
Accessory
Ch. 4 AUX
Pulse During Crank
Ch. 5 AUX
Pulse A�er Shutdown
Ch. 6 AUX
Factory Arm
Ch. 7 AUX
Factory Disarm
AUX Output Control
Any AUX output can be configured using the AUX Control Menu. This feature is only
accessible via FlashLogic Weblink or Weblink Mobile.
1 Second Pulse
30 Second Pulse
5 Second Pulse
Push & Hold
10 Second Pulse
Latch ON/OFF
15 Second Pulse
Latch 10min w/ RS
20 Second Pulse
Latch Run�me
6 Chirp
500ms L, 350ms UL
120sec
6 Chirp
10min
4.0sec
Diesel 30
-14F
Same As Bank 2, F1

Advertisement