Palazzetti Ecopalex Glass Installation, User And Maintenance Manual page 27

Hide thumbs Also See for Ecopalex Glass:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22
5.3
FLUES AND CHIMNEY CAPS
The chimney must be dimensioned in compliance with
EN 13384-1.
Follow the indications in the technical data sheet relating
to the chimney draught.
The flue pipe for the discharge of smoke must be
compliant with standards EN 10683, EN 1856-1-2, EN
1857, EN 1443, EN 13384-1-3, EN 12391-1, EN15287-1
both in terms of size and materials used to construct it.
be at least T400.
A PERFECT DRAUGHT is above all the result
of a flue that is clear of obstructions such as
chokes, horizontal sections or corners; any axial
displacements should be at a maximum angle of
only 30°). These displacements should preferably
be effected near the chimney top.
THE SMOKE PIPE between the fireplace and
as the appliance's smoke outlet. The smoke pipe
must be sealed. It is prohibited to use extendable
chimney, you may perform a maximum of 3 direction
changes no greater than 90°, with the smoke pipe
no longer than 2 m in horizontal projection and a
vertical segment is at least 50 cm before changing
direction.
The CHIMNEY TOP shall be the WINDPROOF type
with an inside cross section equivalent to that of the
and relative table. Near the ridge cap, consider the
less of the two.
chimney respect the distances and measurements
been used it should be cleaned thoroughly to avoid
malfunctions and the danger of unburned parts deposited
once a year.
90°
β
Symbol
Description
Distance measured 90° from
c
the roof surface
Height above the roof ridge
a
Z
Distance (mm)
X > 2000
where A=500 and B=1000
27
a
Buffer zone
(mm)
1300
500
cap
X
X
A
B
Outlet position
Z + A
B
- 5.2 -
- 5.3 -

Advertisement

Table of Contents
loading

Table of Contents