Operation And Storage Temperatures; Current Consumption - Quectel UG96 Hardware Design

Hide thumbs Also See for UG96:
Table of Contents

Advertisement

Voltage drop during
burst transmission
Peak supply current
I
(during transmission
VBAT
slot)
USB_VBUS
USB detection

5.3. Operation and Storage Temperatures

The operation and storage temperatures are listed in the following table.
Table 24: Operation and Storage Temperatures
Parameter
Operation Temperature Range
Extended Temperature Range
Storage Temperature Range
NOTES
1)
1.
Within operation temperature range, the module is 3GPP compliant.
2)
2.
Within extended temperature range, the module remains the ability to establish and maintain a
voice, SMS, data transmission, emergency call, etc. There is no unrecoverable malfunction. There
are also no effects on radio spectrum and no harm to radio network. Only one or more parameters
like P
might reduce in their value and exceed the specified tolerances. When the temperature
out
returns to the normal operating temperature levels, the module will meet 3GPP specifications again.

5.4. Current Consumption

The values of current consumption are shown below.
UG96_Hardware_Design
Maximum power control
level on GSM900
Maximum power control
level on GSM900
Min.
1)
-35
2)
-40
-40
UMTS/HSPA Module Series
2.5
Typ.
Max.
+25
+75
+85
+90
UG96 Hardware Design
400
mV
1.8
2.0
A
5.0
5.25
V
Unit
º C
º C
º C
55 / 76

Advertisement

Table of Contents
loading

Table of Contents