Installation; Positioning And Levelling; Electrical Connection - Ariston CE6VP4R Operating Instructions Manual

Cooker and oven
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14

Installation

 Before operating your new appliance please read
this instruction booklet carefully. It contains important
information concerning the safe installation and
operation of the appliance.
 Please keep these operating instructions for future
reference. Make sure that the instructions are kept with
the appliance if it is sold, given away or moved.
 The appliance must be installed by a qualified
professional in accordance with the instructions
provided.
 Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected
from the electricity supply.

Positioning and levelling

 It is possible to install the appliance alongside
cupboards whose height does not exceed that of the
hob surface.
 Make sure that the wall in contact with the back of
the appliance is made from a non-flammable, heat-
resistant material (T 90°C).
To install the appliance correctly:
• Place it in the kitchen, the dining room or the bed-
sit (not in the bathroom).
• If the top of the hob is higher than the cupboards,
the appliance must be installed at least 600 mm
away from them.
HOOD
600
Min.
mm.
• Do not position blinds behind the cooker or less
than 200 mm away from its sides.
• Any hoods must be installed according to the
instructions listed in the relevant operating manual.
Levelling
If it is necessary to level the
appliance, screw the
adjustable feet into the places
provided on each corner of the
base of the cooker (see figure).
• If the cooker is
installed underneath a
wall cabinet, there must
be a minimum distance
of 420 mm between this
cabinet and the top of
the hob.
This distance should be
increased to 700 mm if
the wall cabinets are
flammable (see figure).
The legs* fit into the slots on
the underside of the base of
the cooker.

Electrical connection

.itting the power supply cable
To open the terminal board:
• Insert a screwdriver into the side tabs of the
terminal board cover.
To install the cable, follow the instructions below:
• Loosen the cable clamp screw and the wire contact
screws.
 The jumpers are pre-set at the .actory for 230 V
single-phase connection (see figure).
230V 1N~
H07RN-F 3x4 CEI-UNEL 35364
N
• To carry out the electrical connections as shown in
the figures, use the two jumpers inside the box (see
figure - labelled “P”).
N
*
Only available in certain models.
• Pull the cover to
open it.
L
P
L1
L2
L3
15
GB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ce6vp6 eu

Table of Contents