Installation; Compliance With Standards; Ventilation - Ariston CPDO 110 AUS Operating, Care And Installation Instructions Manual

Table of Contents

Advertisement

Installation

These instructions have been prepared for use by
authorised persons. This unit must only be installed
by an authorised person.
Remove all packing and other items from inside and
outside the oven before installation.
This appliance must not be installed in marine craft,
caravans or recreational vehicles.

Compliance with standards

This cooktop must be installed in accordance with
the requirements of local gas and electrical
authorities, as well as the latest published versions
of the following standards:
• AS/NZS 5601 Gas Installation code
• SAA Wiring Rules

Ventilation

This unit may be installed and used only in
permanently ventilated rooms. Fresh circulating air is
needed for the proper combustion of gas. If
insufficient air is provided to the gas cooktop,
inefficient combustion and/or the production of
poisonous gases may result.
Adjacent cabinetry
It is recommended that the adjacent kitchen
surfaces should be capable of withstanding
temperatures of 100°C.
• The appliance should be installed next to
cabinetry which is no taller than the top of the
cooker hob.
• The wall in direct contact with the back panel of
the cooker must be made of non-flammable
material. During operation of the cooker, the back
panel of the cooker could reach a temperature of
50°C above room temperature.
• Kitchen cabinets installed next to the cooker that
are higher than the top of the hob, must be at
least 600 mm from the edge of the hob itself.
• If the hood is installed below a wall cabinet, the
latter must be at least 700 mm (millimetres) above
the surface of the hob.
• Cabinets installed adjacent to the hood must be
at least 420 mm above the hob.
The following minimum clearances to combustible
materials must be observed:
• Minimum clearance from edge of cooker to side
wall must be 25 mm.
• Minimum clearance from edge of cooker to rear
wall must be 25 mm.
HOOD
600
Min.
mm.
Range hoods
Range hoods and overhead exhaust fans must be
installed according to manufacturers' instructions
but in no case shall clearance from hob burners be
less than 600 mm for range hoods and 750 mm for
overhead exhaust fans.
• If the hood is installed below a wall cabinet, the
latter must be at least 700 mm (millimetres) above
the surface of the hob.
Levelling The Cooker
If it is necessary to level the appliance, screw the
adjustable feet into the places provided on each
corner of the cooker base.
This appliance must not be installed on a plinth.
Safety Chain
In order to prevent accidental tipping of the
appliance, for example by a child climbing onto the
open oven door, the supplied safety chain must be
installed.
Ensure the chain is secured to the rear wall of the
oven, and attach the chain to a hook or screw
secured to the wall behind the appliance.
GB