About the units and options
15.3 System layout
Installer and user reference guide
48
(a)
To avoid condensation and water dripping out of the unit. If the temperature or the
humidity is beyond these conditions, safety devices may be put in action and the air
conditioner may not operate.
For combination with R32 outdoor unit, refer to the following table:
Outdoor units
RZAG71~140
Outdoor
temperature
Indoor
temperature
RZASG71~140
Outdoor
temperature
Indoor
temperature
AZAS71+100
Outdoor
temperature
Indoor
temperature
RZA200+250
Outdoor
temperature
Indoor
temperature
ARXM71
Outdoor
temperature
Indoor
temperature
Indoor humidity
(a)
To avoid condensation and water dripping out of the unit. If the temperature or the
humidity is beyond these conditions, safety devices may be put in action and the air
conditioner may not operate.
DB: Dry bulb
WB: Wet bulb
INFORMATION
The following illustration is an example and might NOT match your system layout.
Cooling
–20~52°C DB
–20~24°C DB
–20~18°C WB
17~38°C DB
10~27°C DB
12~28°C WB
–15~46°C DB
–15~21°C DB
–15~15.5°C WB
20~38°C DB
10~27°C DB
14~28°C WB
–5~46°C DB
–15~21°C DB
–15~15.5°C WB
20~38°C DB
10~27°C DB
14~28°C WB
-20~46°C DB
-20~15°C WB
14~28°C WB
10~27°C DB
-10~46°C DB
-15~18°C WB
14~28°C WB
10~30°C DB
(a)
≤80%
Split system air conditioner
Heating
—
FAA71+100BUV1B
4P654517-1 – 2021.03