3 About the box

WARNING
ALWAYS use multicore cable for power supply cables.
WARNING
Use an all-pole disconnection type breaker with at least
3  mm between the contact point gaps that provides full
disconnection under overvoltage category III.
WARNING
If the supply cord is damaged, it MUST be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
WARNING
Do NOT connect the power supply to the indoor unit. This
could result in electrical shock or fire.
WARNING
▪ Do NOT use locally purchased electrical parts inside
the product.
▪ Do NOT branch the power supply for the drain pump,
etc. from the terminal block. This could result in
electrical shock or fire.
WARNING
Keep the interconnection wiring away from copper pipes
without thermal insulation as such pipes will be very hot.
DANGER: RISK OF ELECTROCUTION
All electrical parts (including thermistors) are powered by
the power supply. Do NOT touch them with bare hands.
DANGER: RISK OF ELECTROCUTION
Disconnect the power supply for more than 10  minutes,
and measure the voltage at the terminals of main circuit
capacitors or electrical components before servicing. The
voltage MUST be less than 50 V DC before you can touch
electrical components. For the location of the terminals,
see the wiring diagram.
Finishing indoor unit installation (see Finishing the outdoor unit
installation)
DANGER: RISK OF ELECTROCUTION
▪ Make sure that the system is earthed properly.
▪ Turn OFF the power supply before servicing.
▪ Install the switch box cover before turning ON the
power supply.
Commissioning (see "10 Commissioning" [ 4  14])
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
CAUTION
Do NOT perform the test operation while working on
the indoor units.
When performing the test operation, NOT ONLY the
outdoor unit, but the connected indoor unit will operate as
well. Working on an indoor unit while performing a test
operation is dangerous.
CAUTION
Do NOT insert fingers, rods or other objects into the air
inlet or outlet. Do NOT remove the fan guard. When the
fan is rotating at high speed, it will cause injury.
Installation manual
6
WARNING: MILDLY FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
3
About the box
3.1

Indoor unit

INFORMATION
The following figures are just examples and may NOT
completely match your system layout.
3.1.1
To remove the accessories from the
indoor unit
1 Remove:
▪ the accessory bag located at the bottom of the package,
▪ the mounting plate attached to the back of the indoor unit.
a
b
c
d
e
a
Installation manual
b
Operation manual
c
General safety precautions
d
Titanium apatite deodorising and silver particle filter
e
Indoor unit fixing screw (M4×12L). Refer to
unit on the mounting
f
Dry battery AAA.LR03 (alkaline) for user interface
g
User interface holder
h
User interface
i
Mounting plate
4

About the unit

WARNING: MILDLY FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
4.1

System layout

NOTICE
Design of the system must not be done at temperatures
below –15°C.
a
a
Indoor unit
b
Service lid
c
Air filter
d
Titanium apatite deodorizing and silver particle filter
e
Refrigerant piping, drain hose and interconnection cable
f
Insulation tape
FTXP20~35N5V1B9 + ATXP20~35N5V1B9
f
g
h
i
"8.3 To fix the
plate" [ 4  13].
b
c
e
d
f
Daikin room air conditioner
3P748643-1 – 2023.07