Electrical Connection; Electrical Connection General Notes - Bosch Rexroth MKE Operating Manual

Synchronous servomotors
Hide thumbs Also See for Rexroth MKE:
Table of Contents

Advertisement

40 / 74

Electrical connection

8.3
Electrical connection
8.3.1
Electrical connection general
notes
WARNING
Risk of explosion due to improper handling
during motor connection!
Make sure that the motor is only connected in de-
energized state and a non-explosive atmosphere.
Before working on the system, always use a suit-
able measuring device (e.g. multimeter) to check
whether any parts of the system are still under
residual voltage (e.g. caused by residual energies
of capacitors in filters and drive units etc.) their
discharge times are to be waited for.
The connection between the protective con-
ductor terminal and the operating ground must
be made before any other connections.
The connection or terminal points to or on the
control unit must be located outside the poten-
tially explosive atmosphere or must be approved
for use in potentially explosive atmospheres.
WARNING
Danger! Electric voltage! Operations in the
vicinity of live parts are extremely dangerous.
Work required on the electric system may
only be carried out by skilled electricians.
Tools for electricians (VDE tools) are abso-
lutely necessary.
Isolate (even auxiliary circuits).
Secure against reactivation.
Ensure de-energization.
Ground and short-circuit.
Cover or shield any adjacent live parts.
Bosch Rexroth AG
MKE Synchronous Servomotors
WARNING
High electric voltage! Danger to life, risk of injury
by electric shock.
While the rotor is rotating, motors with perma-
nent magnet excitation create a voltage > 60 V at
the motor connections.
Any work may only be carried out while the motor
is at standstill.
Never connect or disconnect plug connectors
under load!
NOTICE
Never touch the connection points of electro-
static sensitive devices!
Mounted components e.g. temperature
sensor, encoder) can contain parts suscep-
tible to electrical discharge (ESD).
Observe ESD safety measures.
The electrical connection of MKE motors (EU)
consists of the following components:
Power connection (terminal box)
Encoder connection (terminal box)
Equipotential bonding conductor (ground
conductor)
Power and encoder connection cables are con-
nected within the ATEX terminal box. The open-
ings for the cable entries (Ex-KLE) are closed
with dummy plugs on delivery. Use certified Ex
cable and line entries (EN 60079-14:2014). The
Ex cable and line entries are not included in the
scope of delivery.
Mount the cable glands (Ex-KLE) according to the
manufacturer's specifications.
All connection variants must comply with the
specifications according to
EN 60079-14:2014 point 10.6 ff "Additional
requirements for type of protection "d" - Flame-
proof enclosure".
R911402016, Edition 02