Return to TOC
OUTPUT MENU
The following table describes the parameters on the Output menu.
PARAMETER
CAN INDEX
PWM Duty
0x6700:00
Current
0x66E0:00
TEMPERATURE MENU
The Temperature menu contains the Internal Temperature parameter:
PARAMETER
CAN INDEX
Internal Temperature
0x6618:00
5 — MONITOR PARAMETERS
OUTPUT MENU
VALUES
RAW VALUES
DATA SIZE
0.0–100.0%
16-bit
0–1000
0–1000mA
16-bit
0–1000
TEMPERATURE MENU
VALUES
RAW VALUES
DATA SIZE
–50°C to +120°
16-bit
–500 to +1200
Curtis Model 3301T Digital Instrumentation – September 2021
ACCESS LEVEL
Field
Indicates the PWM percentage when pin 8 is
Intermediate
configured as a driver.
Field
Indicates the current sunk when pin 8 is configured
Intermediate
as a driver.
ACCESS LEVEL
Field
Indicates the temperature of the LCD.
Intermediate
DESCRIPTION
DESCRIPTION
pg. 45