SET HOURMETERS MENU

Use the Set Hourmeters menu to specify the password for resetting hour meters. After the password
has been entered the
reset the hour meters.
Note: The default password for resetting the hour meters is 1234. Curtis recommends that you change
the default password.
Take the following steps to specify the password:
1. Specify the password as the Input Hrm Password parameter value.
2. Set the Confirm Input Password parameter to On. If the password is valid, the Set Hourmeters
PARAMETER
CAN INDEX
Input Hrm Password
0x6906:00
Confirm Input Password
0x6908:00
Status of Set Hourmeters
0x6907:00

Set Hourmeters Submenu

Use the Set Hourmeters submenu to reset the hour meters and to change the password for resetting
hour meters.
PARAMETER
CAN INDEX
Reset KSI Hourmeter
0x646A:00
Reset TRA Hourmeter
0x646B:00
Reset HYD Hourmeter
0x646C:00
Reset STR Hourmeter
0x646D:00
Set KSI Hourmeter
0x642C:00
Change Hrm Password
0x6905:00
pg. 32
Set Hourmeters submenu
submenu is displayed.
SET HOURMETERS MENU
VALUES
RAW VALUES
DATA SIZE
1111–9999
1111–9999
Off/On
0–1
Enumerated
0–1
SET HOURMETERS SUBMENU
VALUES
RAW VALUES
DATA SIZE
Off/On
0–1
Off/On
0–1
Off/On
0–1
Off/On
0–1
0–99999.9 hours
0–999999
1111–9999
1111–9999
is displayed. The submenu contains parameters that
ACCESS LEVEL
DEFAULT VALUE
32-bit
OEM Dealer
5555
32-bit
OEM Dealer
Off
32-bit
OEM Dealer
Disable
ACCESS LEVEL
DEFAULT VALUE
16-bit
OEM Dealer
Off
16-bit
OEM Dealer
Off
16-bit
OEM Dealer
Off
16-bit
OEM Dealer
Off
32-bit
OEM Dealer
0
32-bit
OEM Dealer
1234
DESCRIPTION
Specifies the password for resetting hour meters.
Note: The default value is not the same value as the
actual password.
Submits the password specified with the Input Hrm
Password parameter.
Indicates whether the hour meters can be reset:
0 = Disable
1 = Enable
When a valid hour meter password has been
specified, the value changes to Enable.
RO
DESCRIPTION
Specify On to reset the keyswitch hour meter.
Specify On to reset the traction controller hour meter.
Specify On to reset the pump controller hour meter.
Specify On to reset the steering controller hour meter.
Sets the keyswitch hour meter to a specific value.
Specifies the password for resetting the hour meters.
4 — PROGRAMMABLE PARAMETERS
Return to TOC

Advertisement