Password Menu; Maintenance Menu - Curtis 3301T Manual

Software device profile: 103.0.0.0
Table of Contents

Advertisement

Curtis Model 3301T Digital Instrumentation – September 2021

PASSWORD MENU

The Password parameters specify the passwords for powering on the 3301T and for
editing
Note: The passwords' ranges of values are 1111–4444. However, passwords can only consist of the
digits 1, 2, 3, and 4.
PARAMETER
CAN INDEX
OEM Menu Password
0x6011:00
USER Menu Password
0x600F:00
PIN Code
0x6010:00

MAINTENANCE MENU

The 3301T provides three countdown maintenance monitors. The Maintenance parameters specify
intervals for the maintenance monitors and reset the monitors.
Note: The parameters on the
remains on the maintenance monitors.
PARAMETER
CAN INDEX
Maintenance Interval 1
0x643E:00
Maintenance Interval 2
0x6444:00
Maintenance Interval 3
0x644A:00
Reset Maintenance
Interval 1
0x6471:00
Reset Maintenance
Interval 2
0x6472:00
Reset Maintenance
Interval 3
0x6473:00
pg. 38
parameters.
PASSWORD MENU
VALUES
RAW VALUES
DATA SIZE
1111–4444
32-bit
1111–4444
1111–4444
32-bit
1111–4444
1111–4444
32-bit
1111–4444
Maintenance menu
MAINTENANCE MENU
VALUES
RAW VALUES
DATA SIZE
0.0–3276.7 hours
32-bit
0–32767
0.0–3276.7 hours
32-bit
0–32767
0.0–3276.7 hours
32-bit
0–32767
Off/On
16-bit
0–1
Off/On
16-bit
0–1
Off/On
16-bit
0–1
ACCESS LEVEL
DEFAULT VALUE
OEM Dealer
Specifies the password for accessing parameter
menus that have the OEM access level.
2222
Field Intermediate
Specifies the password for accessing parameter
menus that have the User access level.
1111
Field Intermediate
Specifies the password for powering on the 3301T.
1234
Note: The
PIN Code Source
whether a password is required.
of the Monitor menu indicate how much time
ACCESS LEVEL
DEFAULT VALUE
Field Intermediate
Specifies the countdown interval for maintenance
monitor 1.
999.9 hours
Field Intermediate
Specifies the countdown interval for maintenance
monitor 2.
999.9 hours
Field Intermediate
Specifies the countdown interval for maintenance
monitor 3.
999.9 hours
Field Intermediate
When On is specified, resets maintenance monitor 1.
Off
Field Intermediate
When On is specified, resets maintenance monitor 2.
Off
Field Intermediate
When On is specified, resets maintenance monitor 3.
Off
4 — PROGRAMMABLE PARAMETERS
Return to TOC
viewing and
DESCRIPTION
parameter indicates
DESCRIPTION

Advertisement

Table of Contents
loading

Table of Contents