Odometers Menu; Senders Menu - Curtis 3301T Manual

Software device profile: 103.0.0.0
Table of Contents

Advertisement

Return to TOC

ODOMETERS MENU

The 3301T provides three odometers. The Odometers parameters reset the odometers.
Note: The parameters on the
PARAMETER
CAN INDEX
Reset Odometer 1
0x646E:00
Reset Odometer 2
0x646F:00
Reset Odometer 3
0x6470:00

SENDERS MENU

The Senders parameters specify the types of data received by the
PARAMETER
CAN INDEX
Sender 1 Type
0x6300:00
Sender 2 Type
0x6301:00
Sender 3 Type
0x6302:00
Sender 4 Type
0x6303:00
4 — PROGRAMMABLE PARAMETERS
Odometers menu
ODOMETERS MENU
VALUES
RAW VALUES
DATA SIZE
Off/On
16-bit
0–1
Off/On
16-bit
0–1
Off/On
16-bit
0–1
SENDERS MENU
VALUES
RAW VALUES
DATA SIZE
Enumerated
32-bit
0–3
Enumerated
32-bit
0–3
Enumerated
32-bit
0–3
Enumerated
32-bit
0–3
Curtis Model 3301T Digital Instrumentation – September 2021
of the Monitor menu indicate the odometer data.
ACCESS LEVEL
DEFAULT VALUE
Field Intermediate
When On is specified, resets odometer 1 to 0.
Off
Field Intermediate
When On is specified, resets odometer 2 to 0.
Off
Field Intermediate
When On is specified, resets odometer 3 to 0.
Off
ACCESS LEVEL
DEFAULT VALUE
Field Intermediate
Configures the switch 1 input:
0
0 = Switch Input.
1 = Resistor Input (reserved).
2 = Voltage Input (reserved).
3 = Frequency Input (reserved).
Field Intermediate
Configures the switch 2 input:
0
0 = Switch Input.
1 = Resistor Input (reserved).
2 = Voltage Input (reserved).
3 = Frequency Input (reserved).
Field Intermediate
Configures the switch 3 input:
3
0 = Switch Input.
1 = Resistor Input (reserved).
2 = Voltage Input (reserved).
3 = HYD Fault Input (pump controller).
Field Intermediate
Configures the switch 4 input:
3
0 = Switch Input.
1 = Resistor Input (reserved).
2 = Voltage Input (reserved).
3 = TRA Fault Input (traction controller).
DESCRIPTION
switch 1–4
inputs.
DESCRIPTION
pg. 39