Pi Menu; Misc Menu - Curtis 3301T Manual

Software device profile: 103.0.0.0
Table of Contents

Advertisement

Curtis Model 3301T Digital Instrumentation – September 2021

PI Menu

The 3301T has a proportional/integral current controller, which is configured by the parameters on
the PI menu.
PARAMETER
CAN INDEX
Kp
0x66B0:00
Ki
0x66C0:00

MISC MENU

The following table describes the parameters on the Misc menu.
PARAMETER
CAN INDEX
Mode Saving
0x4800:00
PIN Code Source
0x3102:00
HYD Controller Enable
0x6900:00
Buzzer Alarm
0x6901:00
Programmer Protocol
0x6902:00
Vehicle Config
0x6909:00
Startup Logo Select
0x3108:00
pg. 42
PI MENU
VALUES
RAW VALUES
DATA SIZE
1–100%
16-bit
20–2048
1–100%
16-bit
20–2048
MISC MENU
VALUES
RAW VALUES
DATA SIZE
Off/On
32-bit
0–1
Enumerated
32-bit
0–2
Off/On
32-bit
0–1
Off/On
32-bit
0–1
Enumerated
32-bit
0–1
1–65535
32-bit RW
1–65535
Enumerated
32-bit
0–1
ACCESS LEVEL
DEFAULT VALUE
OEM Dealer
Specifies the proportional gain factor of the current
PI controller.
8%
OEM Dealer
Specifies the integral gain factor of the current
PI controller.
20%
ACCESS LEVEL
DEFAULT VALUE
Field Intermediate
Specifies whether the speed mode is saved when
the 3301T is powered down. On indicates that the
On
speed mode is saved.
Field Intermediate
Specifies whether a password is required when the
3301T is powered up and whether the 3301T or the
None
ECS is used to enter the password:
0 = None. A password is not required.
1 = Internal. The 3301T is used.
2 = External. The ECS is used.
Field Intermediate
Specifies whether fault codes for the hydraulic
controller are displayed. On indicates the fault codes
On
are displayed.
Field Intermediate
Enables or disables the buzzer. On enables
the buzzer.
On
Field Immediate
Specifies the protocol used for a Curtis
programming device:
ESP/SP
0 = ESP/SP. For the serial version of the 1313
Handheld Programmer.
1 = CIT. For the Curtis Integrated Toolkit
and the CANbus version of the 1313
Handheld Programmer.
OEM Dealer
Specifies the type of vehicle that is being used with
the 3301T. The correct value must be entered in
1
order to
view fault
If you are not sure of the correct value, contact your
Curtis distributor or the Curtis sales and support
office in your region.
Field Intermediate
Specifies whether the Curtis logo is displayed when
the 3301T is powered up:
None
0 = None
1 = Curtis
4 — PROGRAMMABLE PARAMETERS
Return to TOC
DESCRIPTION
DESCRIPTION
(CIT)
TM
names.

Advertisement

Table of Contents
loading

Table of Contents