Ignition Coil - Kohler KG2204 Service

Propane, liquefied petroleum gas (lpg) and natural gas (ng) fueled
Hide thumbs Also See for KG2204:
Table of Contents

Advertisement

5.8. Ignition Coil

Figure 5-9 Ignition Coil
WARNING
Electrical shock can cause injury.
Do not touch wires while engine is running.
Refer to the Engine Service Manual, Ignition Coil
Removal and Installation, for more detailed assembly
and disassembly instructions.
96
Installation and Removal Procedures
5.8.1. Removal Procedure
Make sure that the engine is off.
If the engine is used as part of a generator set,
disconnect AC power to the generator set by
opening the upstream circuit breaker.
Disconnect the engine starting battery, negative
(-) lead first.
Shut off the fuel supply.
Disconnect the wire harness and the spark plug
leads from the ignition coil.
Remove the four ignition coil mounting bolts, flat
washers, lock washers, and nuts that secure the
ignition coil to the bracket
Remove the ignition coil.
5.8.2. Installation Procedure
Position the ignition coil on the bracket.
Secure the ignition coil with four ignition coil
mounting bolts, flat washers, lock washers, and
nuts.
Connect the wire harness and spark plugs to the
ignition coil.
Reconnect the battery.
If the engine is used as part of a generator set,
re-apply the AC power supply to the generator set
by closing the upstream circuit breaker.
Turn on the fuel supply.
Start the engine and check for proper operation in
all throttle ranges.
Turn off the engine.
If a DTC code is found, refer to Section 2,
Diagnostic Troubleshooting Codes for further
diagnosis.
TP-6903 5/16a