Kohler KG2204 Service page 24

Propane, liquefied petroleum gas (lpg) and natural gas (ng) fueled
Hide thumbs Also See for KG2204:
Table of Contents

Advertisement

P-Code
SPN
FMI
P0125
110
17
P0126
110
18
P0127
105
16
P0128
110
17
P0129
108
18
P0131
3217
4
P0132
3217
3
P0133
3217
13
P0134
3217
31
P0137
3227
4
P0138
3227
3
P0139
3227
13
P0140
3227
31
P0151
3256
4
P0152
3256
3
P0153
3256
13
24
Diagnostic Troubleshooting Codes
Description
Insufficient Coolant
Temperature for Closed
Loop Fuel Control
Insufficient Coolant
Temperature for Stable
Operation
Intake Air Temperature
Too High
Coolant Thermostat
(Coolant Temperature
Below Thermostat
Regulating
Temperature)
Barometric Pressure
Too Low
HEGO sensor Circuit
Low Voltage (B1S1)
HEGO sensor Circuit
High Voltage (B1S1)
HEGO sensor Circuit
Slow Response (B1S1)
HEGO sensor No
Activity Detected (B1S1)
O2 Sensor Circuit Low
Voltage (B1S2)
O2 Sensor Circuit High
Voltage (B1S2)
O2 Sensor Circuit Slow
Response (B1S2)
O2 Sensor No Activity
Detected (B1S2)
O2 Sensor Circuit Low
Voltage (B2S1)
O2 Sensor Circuit High
Voltage (B2S1)
O2 Sensor Circuit Slow
Response (B2S1)
Possible Cause
 Problem with the CT
sensor or leads.
 Problem with the CT
sensor or leads.
 Blocked CAC, cabin
fan not working,
intake air duct
separated.
 Problem with the CT
sensor or leads.
 Actual atmospheric
condition, TMAP
sensor/leads if you
also have a TMAP
fault.
 Problem with the
HEGO sensor or
leads.
 Problem with the
HEGO sensor or
leads.
 Problem with the
HEGO sensor or
leads.
 Problem with the
HEGO sensor or
leads.
 Not applicable
 Not applicable
 Not applicable
 Not applicable
 Not applicable
 Not applicable
 Not applicable
Corrective Action
 Check CT sensor leads. Refer to
Section 4.3.
 Replace CT sensor. Refer to
Section 5.2.
 Check CT sensor leads. Refer to
Section 4.3.
 Replace CT sensor. Refer to
Section 5.2.
 Clean debris from air cleaner.
 Check the fan leads.
 Check the fan fuses.
 Reconnect intake air duct.
 Check CT sensor leads. Refer to
Section 4.3.
 Replace CT sensor. Refer to
Section 5.2.
 Replace the TMAP sensor. Refer
to Section 5.10.
 Troubleshoot the HEGO sensor
for bad leads. Refer to
Section 4.7.
 Replace the HEGO sensor. Refer
to Section 5.7.
 Troubleshoot the HEGO sensor
for bad leads. Refer to
Section 4.7.
 Replace the HEGO sensor. Refer
to Section 5.7.
 Troubleshoot the HEGO sensor
for bad leads. Refer to
Section 4.7.
 Replace the HEGO sensor. Refer
to Section 5.7.
 Troubleshoot the HEGO sensor
for bad leads. Refer to
Section 4.7.
 Replace the HEGO sensor. Refer
to Section 5.7.
 Not applicable
 Not applicable
 Not applicable
 Not applicable
 Not applicable
 Not applicable
 Not applicable
TP-6903 5/16a