FujiFilm GW690 2 Factory Service Manual And Parts List page 42

Table of Contents

Advertisement

REASSEMBLY AND ADJUSTMENT
FUJI PROFESSIONAL GW69011, GSW69011
3 - 3
Installing the range/viewfinder assembly (5 - 1)
1)
After checking the linkage (5
-
37) to insure that it is not deformed or
tilted, set the range scale to 1 m, and wind up the film advance lever.
2)
Push to move the interlock rod (7
-
123) to the lens barrel side, apply
the face of the linkage (5 - 37) to the interlock rod (7 - 123), fit the
range/viewfinder assembly (5 - 1) to the chassis, and secure it with three
screws (1 - 3).
3)
Move the focusing ring, and make sure that the moving viewfinder frame
(5
-
65) and moving frame assembly (5 - 12) operate smoothly.
3 - 4
Adjustment of focusing position
1)
Set the shutter speed selector ring to "T", wind up the film advance
lever, and thus, fully open the shutter
(Shutter : Bulb; Aperture : Fully opened).
2)
Place the camera on a collimater, turn the focusing ring from the close - up
distance to the infinity several times.
When the focusing ring stops at
the stopper in the infinite position, set the position at 0.03 mm toward
the lens side from the rail plane, and assuming this position as zero,
adjust the position within ±0.01.
Now, tighten three set screws (7 - 65)
evenly.
3)
After adjusting the focusing position, turn the focusing ring from the
middle range to the infinity several times, and make sure again that the
focusing position is correct.
Rated focusing position:
0.03±0.01 toward the lens side from the rail plane
NOTE:
Before performing the above adjustment, thoroughly clean the
mirror (focusing position adjusting base) and rail plane of the
camera.