REASSEMBLY AND ADJUSTMENT
FUJI PROFESSIONAL GW69011, GSW69011
1 - 9
Combining the front mask assembly (7
-
84) with the helicoid assembly (7 - 62)
1)
Place the front mask assembly (7 - 84) on the helicoid assembly (7
-
62),
apply the lead wire through the hole (M) of the cover plate (7 - 219), and
install the cover plate (7
-
219) with four screws (7 - 97) together with the
front mask assembly (7 - 84).
Tighten the screws securely.
(Tightening torque :
About 7 kg - cm)
2)
Install the interlock plate (7 - 73) on the male helicoid (7 - 67) with two
screws (7 - 72).
3)
Pass the lead wire through the hole (m) of the light shielding mask
(7 - 111), apply the PCB (7
-
30) and lug (7
-
40), and tighten three screws
(7 - 112).
Connect the lead wires to the PCB (7 - 30) by means of a soldering.
4)
Installing the positioning plate assembly (7 - 113)
Install the moquette (7 - 213) to cover up the gap between the front mask
assembly (7
-
84) and light shielding mask (7 - 111) with adhesive.
Now, insert the gear shaft (7 - 124) into the hole of the gear (7 - 119) of
the positioning plate assembly (7
-
113), and install the positioning
plate
assembly (7
-
113) with two screws (7
-
120).
5)
Connect the lead wire (7 - 215) to the PCB (7 - 30) and synchrocontact
(7 - 39) by the use of a soldering iron, and after passing the lead wire
through the space between the front mask assembly (7
-
84) and light
shielding mask (7 - 111), secure the lead wire with a piece of tape at the
middle.
-
26-