Power Requirements; Environmental Requirements; Vhsi Ports; Power Consumption - Eicon Networks Eiconcard C90 Installation Manual

Eiconcard series
Hide thumbs Also See for Eiconcard C90:
Table of Contents

Advertisement

Power requirements

Eiconcard
Eiconcard S90
Eiconcard S91S/T
Eiconcard S91 V2
Eiconcard S94
Eiconcard S94/66MHz

Environmental requirements

• Operating temperature: 0°C to 50°C
• Operating humidity: 0 to 90% (non-condensing)
• Barometric operating pressure: 86 to 106 kPascals
• Maximum tolerance in power supply variation: +5% to -5%

VHSI ports

• VHSI ports connect to 36-pin high-density male connectors
• Support for V.24, V.35, EIA-530, and V.36/RS-449
• X.21 with V.11 (X.27) signaling
• Internal or external clocking (DTE or DCE) or split (transmit internal, receive
external)

Power consumption

Warning: Check that power supply will not be overloaded. Maximum
power consumption of the board is stated above. The user should
check that the total power drawn by the host computer, the Eiconcard,
and any other peripherals, does not exceed the capability of the host
power supply unit.
34
+5V
1 A
1 A
.7 A
1.8 A
1.8 A
Technical specifications Eiconcard S series
+12V
-12V
45 mA
50 mA
45 mA
50 mA
45 mA
50 mA
45 mA
50 mA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents