Capacity Tables
(b) Indoor Condition: 25°C DB, 19°C WB
Outdoor Condition: 35°C DB
EWB
EDB
24
19
25
27
Repeat the same process for (c) & (d) in 1
(c) x
= 1.69 kW; y
= 1.63 kW; z
3
3
2
Step:
nd
To obtain the TC, SC & PI for
(a) Indoor Condition: 25°C DB, 17°C WB
Outdoor Condition: 35°C DB
EWB
EDB
16
17
25
19
Repeat the same process for (b) in 2
(c) x
= 1.74 kW; y
= 1.52 kW; z
6
6
3
Step:
rd
To obtain the TC, SC & PI for
(a) Indoor Condition: 25°C DB, 17°C WB
Outdoor Condition: 37°C DB
EWB
EDB
25
17
By Interpolation Method
37°C – 35°C
=
40°C – 35°C
1.74kW – 1.87kW
⇒ x = 1.82kW
44
Outdoor temperature
35°C
TC
SC
PI
1.99
1.32
0.64
x
y
z
2
2
2
1.99
1.53
0.64
Step
st
= 0.68 kW
3
Outdoor temperature
35°C
TC
SC
PI
1.81
1.75
0.63
x
y
z
5
5
5
1.99
1.39
0.64
Step
nd
= 0.68 kW
6
Outdoor temperature
35°C
TC
SC
PI
1.87
1.63
0.63
x – 1.87kW
By Interpolation Method
25°C – 24°C
27°C – 24°C
⇒ x
= 1.99kW
2
Similarly,
y
= 1.39kW
2
z
= 0.64kW
2
(d) x
= 1.83 W; y
4
By Interpolation Method
17°C – 16°C
19°C – 16°C
⇒ x
= 1.87kW
5
Similarly,
y
= 1.63kW
5
z
=0.63kW
5
37°C
TC
SC
PI
x
y
z
Similarly,
y = 1.59kW
z = 0.65kW
x
– 1.99kW
2
=
1.99kW – 1.99kW
= 1.30 kW; z
4
4
x
– 1.81kW
5
=
1.99kW – 1.81kW
40°C
TC
SC
PI
1.74
1.52
0.68
= 0.69 kW