6. Wiring
WARNING
• Do not turn ON the safety breaker until all work is
completed.
1) Strip the insulation from the wire (20 mm).
2) Connect the connection wires between the indoor
and outdoor units so that the terminal numbers
match. Tighten the terminal screws securely. We
recommend a flathead screwdriver be used to
tighten the screws.
Observe the notes mentioned below when wiring to the power supply
terminal board.
Precautions to be taken for power supply wiring.
(Use a round crimp-style terminal for connection to the power
supply terminal board. In case it cannot be used due to
unavoidable reasons, be sure to observe the following instruction.)
CAUTION
When connecting the connection wires to the terminal board using a single core wire, be sure to perform curling.
Problems with the work may cause heat and fires.
Stripping wire at terminal block
3) Pull the wire and make sure that it does not disconnect. Then fix the wire in place with a wire stop.
Terminal block
COMP
Round crimp-style
terminal
Excessive strip length
may cause electrical
Strip wire end to
shock or leakage.
this point.
Good
Installation Guideline
Earth screw
N
Stranded Wire
Wrong
21