Thank you for purchasing RATH’s 12v Tower Phone. We are the largest Emergency Communication Manufacturer in North America and have been in business for over 35 years. We take great pride in our products, service, and support. Our Emergency Products are of the highest quality.
Description Figure 1: Front & Back View Features: • ADA compliant (hands free operation) • LED call status indicator Panel 1 • Powder coated steel construction inside and out • Aluminum access panels powder coated inside and out • Weather and vandal resistant •...
Items Needed for Installation • Concrete for 16” deep, 2’ diameter • 1/4” spanner adapter (provided to remove access panels) • RATH Kit 7476* or 7477** • Adjustable wrench ® • Analog phone line (if using a Landline) • #1 Phillips screwdriver •...
Page 5
LTE Cellular (Units Are Carrier Specific): 1. Open the Cellular Gateway by unscrewing the screw on the left side of the front cover with a Phillips screwdriver and gently pull up on the left side. 2. Insert standard size SIM card (25mm x 15mm) into J4 with the perforated edge first and the gold contact side facing downward.
Phone Programming 1. You can program the phone on-site or remotely. Note: Cellular applications cannot be remotely programmed. 2. If programming on-site, remove the face plate. Use the #10 spanner bit provided to remove the 6 security screws. 3. Remove the cover of the NEMA 4 enclosure by loosening the 4 corner screws. On-Site Programming: Step 1: To Begin Program Mode A.
If you have answered YES to all questions, you have successfully installed and tested the phone. If you answer NO to any question, proceed to the Troubleshooting Section. *RATH recommends the Tower be tested on a regular basis to ensure proper operation.
Troubleshooting Problem Possible Cause & Solutions No dial tone when the • Check to make sure the phone line is connected to SmartPhone board. button is pushed: • Verify dial tone and voltage on phone line going into unit. Audio is low from the speaker: •...