AIR CONDITIONER (MULTI TYPE)
Installation Manual
R410A
For commercial use
Indoor Unit
Model name:
<Floor Standing Type>
MMF-UP0151H-E
MMF-UP0181H-E
MMF-UP0241H-E
MMF-UP0271H-E
MMF-UP0361H-E
MMF-UP0481H-E
MMF-UP0561H-E
English

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba MMF-UP0151H-E

  • Page 1 AIR CONDITIONER (MULTI TYPE) Installation Manual R410A For commercial use Indoor Unit Model name: <Floor Standing Type> MMF-UP0151H-E MMF-UP0181H-E MMF-UP0241H-E MMF-UP0271H-E MMF-UP0361H-E MMF-UP0481H-E MMF-UP0561H-E English...
  • Page 2: Table Of Contents

    – 1 – Contents Original instruction Please read this Installation Manual carefully before installing the Air Conditioner. • This Manual describes the installation method of the indoor unit. 1 Precautions for safety ..........3 •...
  • Page 3 MMF-UP0181H-E work on the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been MMF-UP0241H-E instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work.
  • Page 4: Precautions For Safety

    – 3 – Precautions for safety  Warning indications on the air conditioner unit Warning indication Description The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual. WARNING WARNING WARNING ELECTRICAL SHOCK HAZARD ELECTRICAL SHOCK HAZARD General Disconnect all remote...
  • Page 5 • When work is performed at heights, use a ladder which complies with Installation the ISO 14122 standard, and follow the procedure in the ladder’s • Install the air conditioner securely in a location where the base can instructions. Also wear a helmet for use in industry as protective gear sustain the weight adequately.
  • Page 6 – 5 – Electrical wiring • If there is any kind of trouble (such as check code display has • Only a qualified installer (*1) or qualified service person (*1) is appeared, smell of burning, abnormal sounds, the air conditioner fails allowed to carry out the electrical work of the air conditioner.
  • Page 7 CAUTION R410A refrigerant air conditioner installation • This air conditioner adopts the HFC refrigerant (R410A) which does not destroy ozone layer. • The characteristics of R410A refrigerant are; easy to absorb water, oxidizing membrane or oil, and its pressure is approx. 1.6 times higher than that of refrigerant R22.
  • Page 8: Accessory Parts

    – 7 – Accessory parts Selection of installation place Avoid installing in the following places Attached position Part name Q’ty Shape Stored position Select a location for the indoor unit where the cool or warm air will circulate evenly. Avoid installation in the following kinds of locations. Upper part of main unit Bracket for fixing to wall •...
  • Page 9: Installation

    Installation  Installation space (Unit: mm) Reserve sufficient space required for installation or service work. CAUTION 200 or 50 or more 50 or more*1 more Strictly comply with the following rules to prevent damage of the indoor units and human injury. •...
  • Page 10 – 9 –  Installation of indoor unit Fixing to the floor Use the attached floor fixing bracket to fix the lower ■ External views (Unit: mm) right and left sides of the indoor unit to the floor. REQUIREMENT Bracket for To fix to the indoor unit, use the side plate screws and fixing to wall In case of installing the indoor unit to the floor and the...
  • Page 11  Installation of remote controller (sold separately) Rear Case of Remote Controller Install the remote controller sold separately as follows. Square Hole <RBC-ASCU11- > Rear Case of Remote Controller (1) Untie the cord of the air intake grille and remove the air intake grille. Remote Controller (2) Unfasten the two screws fastening the upper cabinet.
  • Page 12: Drain Piping

    – 11 – Drain piping  Wireless remote controller (sold separately) The signal receiving unit of indoor unit can receive a signal by distance within approx. 7 m. Based upon it, determine a place where the remote controller is operated and the installation place. CAUTION •...
  • Page 13  Connecting drain pipe • To connect drain hose on left • To connect drain hose on right Drain pan Heat insulator Hard polyvinyl chloride pipe Refrigerant Drain pan Drain pan piping PVC pipe PVC pipe (Drain piping) (Drain piping) Drain hose Adhesion for hard polyvinyl chloride pipe used...
  • Page 14: Refrigerant Piping

    – 13 – Refrigerant piping  Airtight test / Air purge, etc. Tightening connection For air tightness test, vacuum drying and adding  Permissible piping length and CAUTION refrigerant, refer to the Installation Manual attached CAUTION to the outdoor unit. height difference Do not apply excessive torque.
  • Page 15: Electrical Connection

    Electrical connection  Power supply wire and communication wires specifications Power supply wire and communication wires are locally procured. For the power supply specifications, follow to the table below. If capacity is little, it is dangerous because overheat WARNING or burnout may be caused. For specifications of the power capacity of the outdoor unit and the power supply wires, refer to the Installation •...
  • Page 16 – 15 – <In the case of combining with outdoor units of Super Modular Multi System u series (SMMS-u)> <In the case of combining with outdoor units other than Super Modular Multi System u series (SMMS-u)> Follow the wiring specifications in the table below even when units other than U series are mixed in the indoor units Control wiring between indoor units, and outdoor unit (L2, L3) and remote controllers to be connected.
  • Page 17  Remote controller wiring  Wiring between indoor and outdoor units • 2-core with non-polarity wire is used for the remote controller wiring and group remote controllers wiring. NOTE Remote controller wiring, remote controller inter-unit Wire size: 0.5 mm² to 2.0 mm² A wiring diagram below is an example for connection to SMMS-u series.
  • Page 18 – 17 –  Wire connection  Remote controller wiring Strip off approx. 9 mm the wire to be connected. <Positioning of hole for wiring (Knock-out hole) > REQUIREMENT UP036 to UP056 UP015 to UP027 • Connect the wires matching the terminal numbers. Wiring diagram Incorrect connection causes a trouble.
  • Page 19: Applicable Controls

    Applicable controls  To secure better effect of Each time [ ] setting button is pushed, indoor unit numbers in the group control heating change cyclically. Select the indoor unit to  Applicable controls setup REQUIREMENT change settings for. When it is difficult to obtain satisfactory heating due to (settings at the site) •...
  • Page 20: Test Run

    – 19 – Test run  Remote controller sensor When the indoor unit has a built-in remote controller, the remote controller sensor is unavailable.  Before test run Wired remote controller The temperature sensor of the indoor unit senses room temperature usually.
  • Page 21: Maintenance

    Maintenance <Daily maintenance> Close the intake grille and fasten the screws Wireless remote controller (two places). ▼Cleaning of air filter Turn on the circuit breaker, then push the Be sure to stop the air conditioner before cleaning of air <Overview of test run operations using the wireless Turn on the power of the air conditioner.
  • Page 22: Troubleshooting

    – 21 – Troubleshooting ▼Periodic Maintenance For environmental conservation, it is strongly recommended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner. When the air conditioner is operated for a long time, periodic maintenance (once a year) is recommended. ...
  • Page 23 Check method On the wired remote controller, central control remote controller and the interface P.C. board of the outdoor unit (I/F), a check display LCD (Remote controller) or 7-segment display (on the outdoor interface P.C. board) to display the operation is provided.
  • Page 24 – 23 – Check code Wireless remote controller Outdoor unit 7-segment display Sensor block display of receiving unit Check code name Judging device Wired remote controller display Auxiliary code Operation Timer Ready Flash 01: TE1 sensor 02: TE2 sensor TE1,TE2 or TE3 sensor trouble 03: TE3 sensor 01: TL1 sensor 02: TL2 sensor...
  • Page 25 Check code Wireless remote controller Outdoor unit 7-segment display Sensor block display of receiving unit Check code name Judging device Wired remote controller display Auxiliary code Operation Timer Ready Flash — Model mismatch of indoor and outdoor unit — — Indoor unit centre unit duplicated Indoor unit —...
  • Page 26 – 25 – Check code Wireless remote controller Outdoor unit 7-segment display Sensor block display of receiving unit Check code name Judging device Wired remote controller display Auxiliary code Operation Timer Ready Flash 01: Comp. 1 side 02: Comp. 2 side IPM short protection trouble Compressor inverter 03: Comp.
  • Page 27: Specifications

    TOSHIBA CARRIER CORPORATION Model Weight (kg) 336 Tadehara, Fuji-shi, Shizuoka-ken 416-8521 JAPAN Cooling Heating MMF-UP0151H-E MMF-UP0181H-E TCF holder: TOSHIBA CARRIER EUROPE S.A.S Route de Thil MMF-UP0241H-E 01120 Montluel FRANCE MMF-UP0271H-E MMF-UP0361H-E Hereby declares that the machinery described below: MMF-UP0481H-E MMF-UP0561H-E...
  • Page 28 – 27 – WARNINGS ON REFRIGERANT LEAKAGE  Important Check of Concentration Limit ▼NOTE 2 The room in which the air conditioner is to be installed requires a design that in the event of refrigerant The standards for minimum room volume are as follows. gas leaking out, its concentration will not exceed a set limit.
  • Page 29 55-EN 56-EN – 28 –...
  • Page 30 EB99841501...

Table of Contents