  • Page 1: Installation Manual

    AIR CONDITIONER (MULTI TYPE) Installation Manual Indoor Unit Model name: Floor Standing Type MMF-AP0154H-E MMF-AP0364H-E MMF-AP0184H-E MMF-AP0484H-E MMF-AP0564H-E MMF-AP0244H-E MMF-AP0274H-E English Installation Manual...
  • Page 2: Table Of Contents

    Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work.
  • Page 3: Warning Indications On The Air Conditioner Unit

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type Warning indications on the air conditioner unit Definition of Protective Gear When the air conditioner is to be transported, installed, maintained, repaired or removed, wear protective gloves and ‘safety’ work clothing. Warning indication Description In addition to such normal protective gear, wear the protective gear described below when undertaking the special...
  • Page 4: Precautions For Safety

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type – 3 – Precautions for Safety Installation • Install the air conditioner securely in a location where the base can sustain the weight adequately. If the strength is not enough, the unit may fall down resulting in injury.
  • Page 5 Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type Test run CAUTION • Before operating the air conditioner after having completed the work, check that the electrical control box cover of the indoor unit and service panel of the outdoor unit are closed, and set the circuit breaker to the ON position. You may New Refrigerant Air Conditioner Installation receive an electric shock if the power is turned on without first conducting these checks.
  • Page 6: Accessory Parts

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type – 5 – Accessory Parts Selection of Installation Place Avoid installing in the following places. Attached position Part name Q’ty Shape Stored position Select a location for the indoor unit where the cool or warm air will circulate evenly. Avoid installation in the following kinds of locations.
  • Page 7: Installation

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type Installation Installation space (Unit: mm) Reserve sufficient space required for installation or service work. A hole on the wall fixing bracket for the indoor unit is a CAUTION long hole.
  • Page 8: Drain Piping

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type – 7 – Drain Piping Indoor unit fixing figure (Example) Installation of remote controller (Sold separately) Bracket for fixing to wall CAUTION For installation of the wired remote controller, follow the Installation Manual attached with the remote controller.
  • Page 9: Check The Draining

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type Connecting drain pipe • To connect drain hose on left The following materials for piping work and insulating process are procured locally. Refrigerant Drain pan piping Drain pan Heat insulator PVC pipe (Drain piping)
  • Page 10: Refrigerant Piping

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type – 9 – Refrigerant Piping Open the valve fully • Use two wrenches to connect the indoor unit pipe. Open the valve of the outdoor unit fully. Projection margin in flaring: B (Unit: mm) CAUTION Outer dia.
  • Page 11: Electrical Connection

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type Electrical Connection ▼ Power supply 220 V – 240 V ~, 50 Hz Power supply 220 V ~, 60 Hz REQUIREMENT WARNING Power supply switch / circuit breaker or power supply wiring / fuse rating for indoor units should be selected by the accumulated total current values of the indoor units.
  • Page 12: Address Setup

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type – 11 – Wiring between indoor and outdoor units Wire connection Indoor / Outdoor control wire / Remote controller terminal block Power supply NOTE REQUIREMENT terminal block An outdoor unit connected with control wiring between indoor and outdoor units wire becomes automatically the •...
  • Page 13: Applicable Controls

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type Applicable Controls Filter sign setting Each time button is pushed, indoor unit numbers in the control group change cyclically. Select the indoor unit to change According to the installation condition, the filter sign Basic procedure for changing REQUIREMENT term (Notification of filter cleaning) can be changed.
  • Page 14: Test Run

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type – 13 – Test Run Remote controller sensor Wired remote controller Wireless remote controller Remove a small screw which fixes the 2, 4 The temperature sensor of the indoor unit senses room nameplate of the receiver unit.
  • Page 15: Maintenance

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type Maintenance ▼ Inspection before maintenance Following inspection must be carried out by a qualified installer or qualified service person. <Daily maintenance> Parts Inspection method CAUTION Access from inspection opening and remove the access panel. Examine the heat exchanger if there Heat exchanger ▼...
  • Page 16: Troubleshooting

    Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type – 15 – Troubleshooting Confirmation and check Confirmation of error log When an error occurred in the air conditioner, an error When an error occurred on the air conditioner, the error code and indoor UNIT No.
  • Page 17 Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type Check method On the wired remote controller, central control remote controller and the interface P.C. board of the outdoor unit (I/F), a check display LCD (Remote controller) or 7-segment display (on the outdoor interface P.C. board) to display the operation is provided.
  • Page 18 Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type – 17 – Check code Wireless remote controller Outdoor unit 7-segment display Sensor block display of receiving unit Check code name Judging device Wired remote AI-NET central controller display control display Auxiliary code Operation...
  • Page 19 Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type Check code Wireless remote controller Outdoor unit 7-segment display Sensor block display of receiving unit Check code name Judging device Wired remote AI-NET central controller display control display Auxiliary code Operation Timer...
  • Page 20 Batch alarm of general-purpose equipment control interface Differs according to error contents of unit with occurrence of alarm Group control follower unit error TCC-LINK — — (L20 is displayed.) Decrease of No. of indoor units TCC-LINK: TOSHIBA Carrier Communication Link. 37-EN 38-EN...
  • Page 21: Specifications

    * Under 70 dBA Hereby declares that the machinery described below: Generic Denomination: Air Conditioner Model / type: MMF-AP0154H-E, MMF-AP0184H-E, MMF-AP0244H-E, MMF-AP0274H-E, MMF-AP0364H-E, MMF-AP0484H-E, MMF-AP0564H-E Commercial name: Super Modular Multi System Air Conditioner Super Heat Recovery Multi System Air Conditioner Mini-Super Modular Multi System Air Conditioner (MiNi-SMMS series) Complies with the provisions of the “Machinery”...
  • Page 22 Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type – 21 – Warnings on Refrigerant Leakage Important Check of Concentration Limit The room in which the air conditioner is to be installed requires a design that in the event of refrigerant 2) When there is an effective opening with the adjacent room for ventilation of leaking refrigerant gas (opening gas leaking out, its concentration will not exceed a set limit.
  • Page 23 Installation Manual Installation Manual SMMS Floor Standing Type SMMS Floor Standing Type 43-EN 44-EN – 22 –...

Table of Contents