ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS
FUNCTION 18
LINE CONTACTOR DROP OUT TIME
DELAY
( Push CONT 3 )
This function allows for the adjustment of the time
allowable for the control to be idle before the line contactor
opens.
Range
Setting
Resolution
Example:
FUNCTION 19
FIELD CURRENT RAMP RATE DURING
REGEN/PLUGGING
( Push CONT 4 )
This function adjusts the rate at which field current ramps
to full value during regenerative or plug braking.
Range
Setting
Resolution
Example:
FUNCTION 20
MPH OVER SPEED LIMIT
( Push CONT 5)
This function adjusts the value of the over speed limit of the
control.
Resolution
Example:
Important Note: The function is used to optimize motor and
control performance and this setting will be determined by
GE and OEM engineers at the time of vehicle development.
This setting must not be changed by field personnel without
the permission of the OEM.
FUNCTION 21
RATE FIELD CHANGES IN OVERSPEED
(Push CONT 6)
This function adjusts how quickly the control responds to
an over speed condition (as defined by the setting value of
function 20). A higher setting will result in the control
requiring a longer response time to an over speed
condition.
Range
Setting
Resolution
Example:
0 to 25.5 seconds
0 to 255
0.1 seconds per set unit
Setting of 255 = 25.5 seconds
0 to 0.255 seconds
0 to 255
0.001 seconds per set unit
Setting of 12 = 0.012 seconds
1 MPH per set unit
Setting of 28 = 28 MPH
0 to 0.255 seconds
0 to 255
0.001 seconds per set unit
Setting of 2 = 0.002 seconds
Important Note: The function is used to optimize motor and
control performance and this setting will be determined by
GE and OEM engineers at the time of vehicle development.
This setting must not be changed by field personnel without
the permission of the OEM.
FUNCTION 23
ERROR COMPENSATION
(Push CONT 8)
This function is used to reduce the ripple in field current
due to the interaction between motor field design and the
digital field current regulation circuit. The value for this
function should be set to 32.
Important Note: The function is used to optimize motor and
control performance and this setting will be determined by
GE and OEM engineers at the time of vehicle development.
This setting must not be changed by field personnel without
the permission of the OEM.
FUNCTION 24
FIELD WEAKENING START (or MOTOR
KNEE POINT)
( Push CONT 9)
This function allows for setting the armature current at
which minimum field current will be achieved.
Range
Setting
Resolution
Example:
Important Note: The function is used to optimize motor and
control performance and this setting will be determined by
GE and OEM engineers at the time of vehicle development.
This setting must not be changed by field personnel without
the permission of the OEM.
FUNCTION 25
MONITOR
( Push CONT 10)
This function allows the monitoring of certain control
functions by looking directly at the RAM of the
microprocessor. Because absolute memory locations need
to be known, this function should not be used without
detailed instructions from the GE application engineer.
To ensure optimum operation of the control, this function
must be left with zero stored in this register.
FUNCTION 26
RATIO OF FIELD TO ARMATURE AMPS
Page 34
0 to 350 Amps
0 to 255
1.625 per set unit
Setting of 47 = 76.38 amps.
April 2002