GE IC3645SH7R354D2 Installation And Operation Manual page 26

Separately excited (sx) transistorized motor controllers for neighborhood electric vehicle application
Table of Contents

Advertisement

DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Controller "motor current sensor" input
-57
is too low during running.
MEMORY RECALL
YES
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Defective control.
Traction
•=
Controller
Line contactor tips bounce or are not fully
picked up.
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
The field current exceeds the current limit
-66
of the field transistor.
MEMORY RECALL
YES
SYMPTOM
Control will not operate or is sluggish on
Circuits valid
start up. Line contactor opens.
for
Traction
POSSIBLE CAUSES
Controller
•=Shorted field F1 to F2
•=F1 or F2 terminals shorted to battery
positive (B+) or to battery negative (B-)
•=Binding line contactor
•=Visually inspect tips, clean them with a
solvent.
•=Noise
•=Confirm that all inductive
loads/accessories are suppressed.
•=Excessive motor and control heating
(control is in thermal cutback)
CORRECTIVE ACTIONS
Replace controller unit.
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when the voltage
input from the current sensor is too low (less than
1.43V, -350 amps) during running.
TROUBLE-SHOOTING DIAGRAM
NO GRAPHIC FOR THIS
STATUS CODE
CAUSE OF STATUS INDICATION
This status code will be displayed when the field
transistor exceeds its current limit. The line
contactor will drop out and the key switch will have
to be recycled to restart the control.
TROUBLE-SHOOTING DIAGRAM
KEY SWITCH *
DIRECTIONAL
P1
P2 P3
+12V
P15 P14
P16
Page 26
SWITCH *
*
L
P4
P5
P21 P11 P10
PLUG (23 PIN)
P7 P9
P13 P8 P6
April 2002

Advertisement

Table of Contents
loading

Table of Contents