Scope of delivery
Type label
Documents and software
Application area
Functional principle
VEGATRENN 152 •
3
Product description
3.1 Configuration
The scope of delivery encompasses:
•
VEGATRENN 152
•
Documentation
– This operating instructions manual
– Ex-specific " Safety instructions" (depending on the version)
– If necessary, further certificates
The type label contains the most important data for identification and
use of the instrument:
•
Instrument type
•
Information about approvals
•
Technical data
•
Serial number of the instrument
•
QR code for device documentation
•
Manufacturer information
Move to " www.vega.com" and enter in the search field the serial
number of your instrument.
There you can find the following information about the instrument:
•
Order data
•
Documentation
•
Software
Alternatively, you can find all via your smartphone:
•
Scan the QR-code on the type label of the device or
•
Enter serial number manually in the VEGA Tools app (available
free of charge in the respective stores)
3.2
Principle of operation
VEGATRENN 152 is a double channel [EEx ia] separator for connec-
tion of two 4 ... 20 mA/HART sensors in two-wire version. A separate
power supply is not necessary. As an associated electrical device, it
ensures a galvanic separation between sensor circuit and processing
circuit and thus between Ex and non-Ex areas.
The current signal from the sensor (4 ... 20 mA) is transferred linearly
and galvanically separated to the output. The VEGATRENN 152 is
suitable for bidirectional transmission of HART signals. The HART sig-
nal can be tapped separately for each channel via the front-mounted
HART communication sockets or the terminals.
3.3
Adjustment
No adjustment or configuration of VEGATRENN 152 is necessary. A
parameter adjustment of the connected sensors can be carried out
via the HART communication sockets behind the hinged front cover.
Adjustment of the connected sensors is carried out preferably via a
3 Product description
7