Scope of delivery
Type label
Documents and software
Application area
Functional principle
VEGATRENN 151 •
3

Product description

3.1 Configuration

The scope of delivery encompasses:
VEGATRENN 151
Documentation
– This operating instructions manual
– Ex-specific " Safety instructions" (depending on the version)
– If necessary, further certificates
The type label contains the most important data for identification and
use of the instrument:
Instrument type
Information about approvals
Technical data
Serial number of the instrument
QR code for device documentation
Manufacturer information
Move to " www.vega.com" and enter in the search field the serial
number of your instrument.
There you can find the following information about the instrument:
Order data
Documentation
Software
Alternatively, you can find all via your smartphone:
Scan the QR-code on the type label of the device or
Enter serial number manually in the VEGA Tools app (available
free of charge in the respective stores)
3.2

Principle of operation

VEGATRENN 151 is an [EEx ia] separator for connection of
4 ... 20 mA/HART sensors in two-wire version. A separate power sup-
ply is not necessary. As an associated electrical device, it ensures a
galvanic separation between sensor circuit and processing circuit and
thus between Ex and non-Ex areas.
The current signal from the sensor (4 ... 20 mA) is transferred linearly
and galvanically separated to the output. The VEGATRENN 151 is
suitable for bidirectional transmission of HART signals. The HART
signal can be tapped via the front-mounted HART communication
sockets or the terminals.
3.3

Adjustment

No adjustment or configuration of VEGATRENN 151 is necessary. A
parameter adjustment of the connected sensors can be carried out
via the HART communication sockets behind the hinged front cover.
Adjustment of the connected sensors is carried out preferably via a
3 Product description