Beverage-Air PR1HC-1AS Installation And Operating Instructions Manual

Beverage-Air PR1HC-1AS Installation And Operating Instructions Manual

Hydrocarbon pr refrigerator

Advertisement

Quick Links

INSTALLATION AND OPERATING INSTRUCTIONS
for all Hydrocarbon
PR Refrigerator Models
809-217A Rev B 10/29/2020
SEE BACK COVER FOR
3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105
WARRANTY REGISTRATION
Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web: beverage-air.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PR1HC-1AS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Beverage-Air PR1HC-1AS

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS for all Hydrocarbon PR Refrigerator Models 809-217A Rev B 10/29/2020 SEE BACK COVER FOR 3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105 WARRANTY REGISTRATION Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web: beverage-air.com...
  • Page 2: Table Of Contents

    User Manual for PR Refrigerators Beverage-Air WELCOME Congratulations on your purchase of Beverage-Air food Additionally, Beverage-Air food service equipment has service equipment. Every employee welcomes you to the one of the best warranties in the food service industry, family of satisfied Beverage-Air customers.
  • Page 3: Safety

    R290 equipment. • Clean a dirty condenser with a sharp object. • Use ONLY Beverage-Air factory service parts. Use of • Store gasoline, kerosene or any other flammable non OEM parts can be dangerous because of the design material near the cabinet.
  • Page 4: Safety

    User Manual for PR Refrigerators Beverage-Air SAFETY CAUTION: If it is necessary to move the Refrigerator after removal from the skid, CAUTION remove all doors and carefully push the unit at a point of no more than 36” from the bottom to avoid damage.
  • Page 5: Important Information

    User Manual for PR Refrigerators Beverage-Air IMPORTANT INFORMATION This unit is intended to be used in a commercial application. That includes bars and restaurants. If installed in a residence some commercial service companies may not be able to service it on site.
  • Page 6: Product Information

    Charge (g) / Charge w x d x h (Inches) Door Solid Door Amps Plug (NEMA) (oz) 5-15P PR1HC-1AS 26 1/2 x 34 3/4 x 84 1/8 Full Solid 5-15P PR1HC-1AHS 26 1/2 x 34 3/4 x 84 1/8 2 Half...
  • Page 7: Clearance And Placement

    User Manual for PR Refrigerators Beverage-Air CLEARANCE AND PLACEMENT 12" AT 0" AT REAR 0" AT BOTTOM 0" AT SIDES Placement Consider the following when selecting a location for your Refrigerator: Clearance: • 12 in. at the top • 0.0 in. at the rear, •...
  • Page 8: Unpacking And Set Up

    User Manual for PR Refrigerators Beverage-Air UNPACKING AND SET UP Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim.
  • Page 9: Shelf Installation

    9. Do NOT overload the shelves. The unit is designed to need to be squeezed slightly during installation. use all shelves that are supplied in an equally spaced manner. Contact Beverage-Air customer service if 4. Install all remaining clips. fewer shelves or a different configuration to ensure shelf overloading will not occur.
  • Page 10: Electrical

    User Manual for PR Refrigerators Beverage-Air ELECTRICAL This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
  • Page 11: Door Reversal Instructions

    User Manual for PR Refrigerators Beverage-Air DOOR REVERSAL INSTRUCTIONS 1. Remove hinge cover. 2. Remove door from the unit including the hinge mounting brackets 3. Remove white hole covers from the side of the door opening you would like the hinges to be located (do not throw away).
  • Page 12: Using The Unit

    User Manual for PR Refrigerators Beverage-Air USING THE UNIT Operation is simple, just keep it connected to the correct The temperature was set at the factory at 38 F, but you º power supply and the refrigerator will maintain the can adjust it to your own selected temperature.
  • Page 13: Sequence Of Operations

    User Manual for PR Refrigerators Beverage-Air SEQUENCE OF OPERATIONS COMPONENT OPERATION CONTROLLER ACTION OPERATION CONTROLLER ACTION COMPRESSOR Compressor turns The Compressor Compressor turns The Compressor on when the cabinet Contact is energized off when the cabinet Contact is de- temperature is above...
  • Page 14: Control Panel Display

    User Manual for PR Refrigerators Beverage-Air CONTROL PANEL DISPLAY Icon Operation Meaning Compressor Permanently On Compressor On Blinking Delay, protection or start-up blocked Otherwise Defrost Permanently On Defrost active Blinking Activated manually or from Digital input Otherwise Fans Permanently On...
  • Page 15 User Manual for PR Refrigerators Beverage-Air Relay/Probe Description Terminal Compressor 10,11 Out 1 Out 2 Evaporator Fan 4, 5 Defrost Element 7, 9 Out 3 Out 4 Light (or alarm relay if electronic Lock model) 13, 14 Air/control probe 18, 19 PB1 –...
  • Page 16: Electronic Controller Parameter Changes

    User Manual for PR Refrigerators Beverage-Air ELECTRONIC CONTROLLER PARAMETER CHANGES Note: Key pad has a 3 second lock feature. Set key must be pressed for 3 seconds and released before keys will become active. Key pad will beep when unlocked and normal key pad operations performed.
  • Page 17: Setting The Real Time Clock

    User Manual for PR Refrigerators Beverage-Air SETTING THE REAL TIME CLOCK To set the real time clock, press and release the set button to enter the machine status menu. “Set will appear on the menu. Use the up and down button to scroll to the real time clock menu folder. “Rtc” will appear on the display.
  • Page 18 User Manual for PR Refrigerators Beverage-Air Beverage-Air Rev. 10/20...
  • Page 19 User Manual for PR Refrigerators Beverage-Air Code Description Description Relay Reset Parameters involved to Enable alarm Probe Pb1 failure Active Automatic Ont, Oft Probe Pb2 failure Active Automatic Ont, Oft Probe Pb3 failure Active Automatic Ont, Oft Probe Pb4 failure...
  • Page 20: Cleaning And Maintenance

    User Manual for PR Refrigerators Beverage-Air CLEANING AND MAINTENANCE Cleaning Schedule: Cabinet Condenser coil Gaskets Routine maintenance Daily wipe down Quarterly cleaning Daily inspection, check Annually that hinges are tight to Weekly interior the cabinet. Daily Exterior Cleaning It is much easier to clean on a regular basis than to have to remove stains once they have built up.
  • Page 21: Condenser Cleaning

    User Manual for PR Refrigerators Beverage-Air CONDENSER CLEANING Keeping the condenser coil clean is critical to efficient operation. 1. Unplug unit from power supply. Rotating fan blade can cause CAUTION personal injury. Unplug unit from power supply before beginning to clean...
  • Page 22: Methods For Cleaning Stainless Steel

    User Manual for PR Refrigerators Beverage-Air METHODS FOR CLEANING STAINLESS STEEL Cleaning Needed Cleaning Agent Method of Application Affect on Finish Satisfactory for use on all Areal 20, Lac-O-Nu, Lumin Wash Rub with cloth as directed finishes. Smears and fingerprints O’Cedar Cream Polish, Stainless...
  • Page 23: Help

    User Manual for PR Refrigerators Beverage-Air HELP Trouble Diagnosis for the User Malfunction Possible Cause Likely Solution Connect to proper voltage circuit Replace Unit not plugged in. fuse or reset breaker. No cooling - unit is silent Fuse or circuit breaker tripped.
  • Page 24: For The Service Tech - R290

    User Manual for PR Refrigerators Beverage-Air FOR THE SERVICE TECH - R290 Refrigeration service should only be attempted by a trained trade professional certified to work on R290 systems. Here are some critical service items. Other Information: This list does not qualify anyone to service the unit. It is a Evacuation: It is critical that a refrigeration system be reminder and checklist for the service tech.
  • Page 25: For The Service Tech - Wiring Diagram

    User Manual for PR Refrigerators Beverage-Air FOR THE SERVICE TECH - WIRING DIAGRAM 115V ONE SYSTEM REFRIGERATOR BLACK WHITE 115VAC 60 HZ EVAP FAN RELAY CONTROL CIRCUIT COMPRESSOR DETAIL CONDENSER FAN START RELAY S.C. COMP R.C. COMP RELAY HIGH PRESSURE...
  • Page 26: Limited Warranty

    (87) months from the date of defective. shipment from Beverage-Air, provided upon receipt of the The labor warranty shall be for self-contained units compressor, manufacturer examination shows the sealed only and for standard straight time, which is defined as compressor to be defective.
  • Page 27: Limited Warranty (Continued)

    With the exception of Blast Chillers product is designed for LIMITATION OF LIABILITY: maintaining temperature and not bringing food to a desired Beverage-Air Corporation or their affiliates shall not be temperature therefore cannot be held responsible for this liable for any indirect, incidental, special or consequential function under warranty.
  • Page 28 User Manual for PR Refrigerators Beverage-Air Warranty Registration Register your product online at beverage-air.com/parts-service or fill out and mail the form below. Cabinet Model Number: _____________________________________________ Date Of Installation: _________________ Cabinet Serial Number: _____________________________________________ Location Of Product Business Name: ____________________________________________________...

Table of Contents