DC Inverter Multi VRF System
Error
Code
FP
Malfunction of DC motor
Malfunction of casing top temperature sensor of
FU
compressor 1
Malfunction of casing top temperature sensor of
Fb
compressor 2
Malfunction of exit tube temperature sensor of
Fd
mode exchanger
Malfunction of inlet tube temperature sensor of
Fn
mode exchanger
Malfunction of outdoor ambient temperature
b1
sensor
b2
Malfunction of defrosting temperature sensor 1
b3
Malfunction of defrosting temperature sensor 2
Malfunction of liquid temperature sensor of
b4
sub-cooler
Malfunction of gas temperature sensor of
b5
sub-cooler
Malfunction of inlet temp sensor of gas-liquid
b6
separator
Malfunction of outlet temp sensor of gas-liquid
b7
separator
b8
Malfunction of outdoor humidity sensor
Malfunction of gas temperature sensor of heat
b9
exchanger
bA
Malfunction of oil-return temperature sensor 1
bH
Clock of system is abnormal
Malfunction of inlet tube temperature sensor of
bE
condenser
Malfunction of outlet tube temperature sensor of
bF
condenser
High-pressure sensor and low-pressure sensor
bJ
are connected reversely
bP
Malfunction of temperature sensor of oil-return 2
bU
Malfunction of temperature sensor of oil return 3
bb
Malfunction of temperature sensor of oil return 4
Malfunction of air inlet temperature sensor of
bd
subcooler
Malfunction of liquid inlet temperature sensor of
bn
subcooler
H0
Malfunction of driving board of fan (uniform)
Driving board of fan operates abnormally
H1
(uniform)
Voltage protection of driving board power of fan
H2
(uniform)
H3
Reset protection of driving module of fan
H4
Drive PFC protection of fan
H5
Over-current protection of inverter fan
H6
Drive IPM module protection of fan
H7
Malfunction of drive temperature sensor of fan
H8
Drive IPM high temperature protection of fan
H9
Desynchronizing protection of inverter fan
Malfunction of drive storage chip of inverter
HA
outdoor fan
HH
High-voltage protection of fan's drive DC bus bar
HC
Drive current detection circuit malfunction of fan
HL
Low-voltage protection of fan's drive DC bus bar
Content
Error
Code
J8
High pressure ratio protection of system
J9
Low pressure ratio protection of system
JA
Protection because of abnormal pressure
JC
Water flow switch protection
JL
Protection because high pressure is too low
JE
Oil-return pipe is blocked
JF
Oil-return pipe is leaking
malfunction of driving board of compressor
P0
(uniform)
Driving board of compressor operates
P1
abnormally (uniform)
Voltage protection of driving board power of
P2
compressor (uniform)
Reset protection of driving module of
P3
compressor
P4
Drive PFC protection of compressor
P5
Over-current protection of inverter compressor
P6
Drive IPM module protection of compressor
Malfunction of drive temperature sensor of
P7
compressor
Drive IPM high temperature protection of
P8
compressor
Desynchronizing protection of inverter
P9
compressor
PA
Malfunction of drive storage chip of compressor
High-voltage protection of compressor's drive
PH
DC bus bar
Drive current detection circuit malfunction of
PC
compressor
Low-voltage protection of compressor's drive
PL
DC bus bar
PE
Phase-lacking of inverter compressor
PF
Drive charging circuit malfunction of compressor
PJ
Failure startup of inverter compressor
PP
AC current protection of inverter compressor
PU
AC input voltage of drive of inverter compressor
G0
PV reversed connection protection
G1
PV Anti-islanding protection
G2
PV DC overcurrent protection
G3
PV power generation overload
G4
PV leakage current protection
G5
Phase-lacking protection at power grid side
G6
Phase-lacking protection at power grid side
G7
PV LVRT
G8
Overcurrent protection at power grid side
G9
Drive IPM module protection at power grid side
Low/high input voltage protection at power grid
GA
side
GH
Photovoltaic DC\DC protection