Mounting The Ac Module - LG A1C-V5 Series Installation Manual

Ac module system
Hide thumbs Also See for LG A1C-V5 Series:
Table of Contents

Advertisement

3-7 Mounting the AC module

Before mounting AC module in the PV rack, be aware of the following requirements:
Check that all parts of the product are intact and operational.
Check that the cable connectors are not damaged.
Do not install the AC modules horizontally. It will make it difficult for dust to be washed off by rain
naturally. Accumulation of dust, dirt or soil may be a cause of performance degradation.
When installed on a roof, the PV module must be mounted over a fire-resistant roof. The fire resistance of
the PV module is class C according to ANSI/UL790.
For proper operation, do not remove AC module frame or replace with another frame.
Do not make extra holes on the AC module frame. Additional holes on the frame may weaken the
strength of the frame and cause damage finally.
To avoid the tensile strain from the thermal expansion, it is recommended to leave a space more than
6mm (0.236 inches) between AC modules frames.
Mount LG AC module to PV rack with 4~5N•m torque.
For reliable connection, make sure that the AC module frame and a PV rack are surely fastened enough to
prevent the AC modules from getting loose.
When installing modules in areas of heavy snow, special care should be taken to install the modules in a
manner that provides sufficient strength for meeting local code requirements.
AC Modules
AC Junction Box
Guides for mounting AC modules on the PV racks are explained from next page.
• When an AC module is exposed to light, it supplies a dc voltage to a micro inverter.
Therefore, the LED on the micro inverter will illuminate in red with a condition that it is not
connected to the grid.
• To prevent the danger of the electric shock, do not touch metal parts inside the AC cable connectors.
Rev. 1.0
AC Module System Installation Manual
16

Advertisement

Table of Contents
loading