Product Specifications; Ac Module, Lgxxxa1C-V5 - LG A1C-V5 Series Installation Manual

Ac module system
Hide thumbs Also See for LG A1C-V5 Series:
Table of Contents

Advertisement

9 Product Specifications

9-1 AC module , LGXXXA1C-V5
Parameter
Section
Max.
Power
Tolerance
Voc
Voltage
Vmpp
Tolerance
Isc
Current
Impp
Tolerance
Note : PV module was measured at STC (Standard Test Condition: Irradiation 1,000W/m
Parameter
Power
Voltage
Current
Frequency
Power Factor(adjustable)
CEC Weighted Efficiency
(California Energy Commission)
Max. Number of AC Modules
Parameter
Phase Voltage
Frequency
After the micro inverter got tripped by voltage or frequency abnormality, it takes about 5 min for the AC module
to operate.
If it got tripped by other reasons or it is connected with the utility after sunrise, it takes about 1 min for the AC
module to operate.
1) Refer to 3-12 Connecting Array of AC Modules to Distribution Panel regarding Maximum number of AC Modules.
Rev. 1.0
AC Module System Installation Manual
LG370A1C-V5
370W
42.8V
37.0V
10.82A
10.01A
Section
Inverter Rated Continuous
Nominal(Range)
Nominal Output
Nominal(Range)
1)
DC module
AC module
DC Input
LG375A1C-V5
375W
0% ~ 3%
42.8V
37.2V
–5% ~ +5%
10.83A
10.09A
–5% ~ +5%
AC Output
240VAC
320W
240V (211V ~ 264V)
1.33A
97%
12 EA
Certification
UL1703, IEC61215, IEC 61730, Safety Class II
UL1741, IEEE1547, UL1741SA
IEEE 1547 (Default)
Range
V < 50%
50% ≤ V < 88%
110% ≤ V < 120%
V ≥ 120%
> 60.5 Hz
< 59.3 Hz
LG380A1C-V5
380W
42.9V
37.4V
10.84A
10.17A
2
, Cell temp. 25℃(77℉),1.5AM)
208VAC
208V (183V ~ 229V)
60Hz (59.3Hz ~ 60.5Hz)
1/0.8 leading...0.8 lagging
FCC Part 15 Class B
Clearing Time (s)
0.16
2.00
1.00
0.16
0.16
0.16
320W
1.54A
96.5%
10 EA
99

Advertisement

Table of Contents
loading